Cooper Lighting I8 Series Benutzerhandbuch
Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
08/02/2008 3:00:44 PM
Specifications and Dimensions subject to change without notice.
ADF042290
PHOTOMETRICS
ORDERING INFORMATION
SHIPPING INFORMATION
I8
C a n d e l a
Angle
Along II
45°
Across
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
3547
3547
3547
3526
3528
3516
3477
3393
3233
3394
3104
2822
3281
2757
2455
3138
2426
2159
2967
2149
1921
2771
1873
1698
2548
1640
1486
2305
1415
1317
2041
1196
1266
1759
1021
1196
1465
945
1097
1160
842
953
853
709
769
552
528
581
270
334
271
51
64
17
0
3
1
C o e f fi c i e n t s o f U t i l i z a t i o n
Effective floor cavity reflectance
20%
rc
80%
70%
50%
30%
10%
0%
rw
70 50 30 10
70 50 30 10
50 30 10
50 30 10
50 30 10
0
RCR
0
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
10
Z o n a l L u m e n S u m m a r y
Zone
Lumens
%Lamp
%Fixture
0-30
0-40
0-60
0-90
0-180
0-40
0-60
0-90
0-180
I8-332-UNV-UPL
Electronic Ballast
F28T8-SP35 Lamps
F28T8-SP35 Lamps
2750 Lumens
Spacing criterion:
Spacing criterion:
(II) 1.2 x mounting
height, ( ) 0.9 x
mounting height
Efficiency 96.2%
Test Report:
Efficiency 96.2%
Test Report:
I8332UNVUPL.IES
LER = FL-94
Yearly Cost of 1000
LER = FL-94
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $2.54
2384
28.9
30.0
3656
44.3
46.1
5946
72.1
74.9
7451
90.3
93.9
7935
96.2
100.0
113 113 113 113
110 110 110 110
104 104 104
98 98 98
93 93 93
90
104 99 95 92
100 97 93 90
91 88 86
87 84 82
82 80 79
76
95 87 81 75
91 85 79 74
80 75 71
76 72 69
73 69 66
64
86 77 69 63
84 75 68 62
71 65 60
68 63 59
65 60 57
55
79 68 60 54
77 67 59 53
64 57 52
61 55 51
58 53 49
47
73 61 53 47
71 60 52 46
57 51 45
55 49 44
52 47 43
41
68 56 47 41
66 54 47 41
52 45 40
50 44 39
48 43 38
36
63 51 42 37
61 50 42 36
48 41 36
46 40 35
44 39 34
33
59 46 38 33
57 45 38 33
44 37 32
42 36 32
41 35 31
29
55 43 35 30
54 42 35 30
40 34 29
39 33 29
38 32 28
27
52 40 32 27
50 39 32 27
38 31 27
36 31 26
35 30 26
24
S A M P L E N U M B E R : 8 T I 8 - 3 3 2 - E B 8 2 / P L U S - U P L - U
NOTES:
(1)
Requires use of MC or MPC cord accessories, specify voltage for plugs.
(2)
Use with wide distribution optic only.
(3)
Voltage must be
specified when ordered with plugs, motion sensors or emergency ballasts.
(4)
ER8 and EB8 ballast systems suitable for operation in ambient
environments up to 122°F (50°C) in open uplight configurations.
(5)
Specify voltage.
(6)
For use with Top Connector Box options. See accessories.
(7)
TAP
option available with a maximum of two ballasts, including EM battery pack.
(8)
Not for use in gymnasiums or similar recreational facilities.
(9)
Dimming
ballast must be specified at time of order.
No. of Lamps
3=3 Lamps
Lamp Type
32=32W T8 (4') Lamps
Series
I8=T8 Industrial
Length
Blank=4' Length
8T=8' Length
Voltage
(3)
UNV=Universal
120/277 Voltage
UNC=Universal
347/480 Voltage
120V=120 Volt
277V=277 Volt
347V=347 Volt
480V=480 Volt
Shielding Options
Blank=Open
TBW=Thin White Baffle
FL=Frosted Acrylic Lens & Frame
(2)
CL=Clear Acrylic Lens & Frame
ASY= Asymmetric Directional Louver
(2)
WG=Heavy Duty Wireguard
Distribution Optic
Blank=Medium (Specular Aluminum)
G=Wide (High Reflectance White)
Mounting Arrangement
Blank=Stand Alone
R=Continuous Row Mount
Options
I8 Lamps Installed
L8830=T8 Lamp, 85CRI 3000K
L8835=T8 Lamp, 85CRI 3500K
L8841=T8 Lamp, 85CRI 4100K
L8850=T8 Lamp, 85CRI 5000K
GL=Single Element Fuse
GL=Single Element Fuse
GM=Double Element Fuse
EL=Emergency Installed
(3)
Options
NUA=No Uplight Apertures In Housing
(Cannot be combined w/UPL)
UPL=Uplight Apertures
PI/CPI=Plug-In (1, 2 or 3)
(see ordering information)
TILW=Tandem Inline Wiring
MWS=Modular Wiring System
MS=Aisle Coverage Motion Sensor
(5)
MSO=360° Coverage Motion Sensor
(5)
C3=3' Power Cord
C6=6' Power Cord
MP=Modular Power Receptacle
(1) (3)
PC3-=3' Power Cord & Plug (Specify Voltage)
TAP=Top Access Plate
(7)
TCBP=Top Connector Box Plate
(6)
Packaging
U=Unit Pack
U=Unit Pack
PAL=Palletized
Out of Carton
PALC=Palletized
In Carton
Ballast Type
T8 Systems
EB8 =T8 Electronic Instant Start.
EB8 =T8 Electronic Instant Start.
(4)
Total Harmonic Distortion < 10%
EB8 /PLUS=
T8 Electronic Instant Start.
(4)
High Ballast Factor >1.15.
Total Harmonic Distortion < 10%
ER8 =T8 Electronic Program Rapid Start.
(4)
Total Harmonic Distortion < 10%
ER8 /PLUS= T8 Electronic Program Rapid Start.
High Ballast Factor >1.15.
Total Harmonic Distortion < 10%
DIM=Consult Factory
(9)
No. of Ballast
1, 2 or 3
No. of Ballast
1, 2 or 3
No. of Ballast
1, 2 or 3
Accessories (order separately)
TCB=Top Connector Box
RH-1=Retrofit Hanger
FH-1=Fixture Hook
FL-1=Fixture Loop
SHK=Hook w/ Safety Screw
PC3-=3' Power Cord & Plug (Specify Voltage)
PC6-=6' Power Cord & Plug (Specify Voltage)
AYC-CHAIN/SET/U=(2) Hooks, 36" Chain Sets w/S-
Hooks
(8)
GRIPPLE TOGGLE-=Single Toggle, #2 Cable (Specify 10' or
30')
GRIPPLE LOOP- =Loop Hanger, #2 Cable (Specify 10' or
30')
MC6=6' Modular Power Cord
MPC6=6' Modular Power Cord & Plug (Specify
Voltage)
MMS-CPD1200H=Aisle Motion Sensor, Box, Modular
Power Receptacle (120/277V)
MMS-CPD500H=360° Motion Sensor, Box, Modular
Power Receptacle (120/277V)
Door Frames (for Field Installation)
Door Frames (for Field Installation)
I8-FRM/LENS PK=Frosted Acrylic Lens & Frame (I8)
I8-FRM/CL PK=Clear Acrylic Lens & Frame (I8)
WG/I8-4FT-B=Heavy Duty Wireguard (I8)
BAFFLE 4FT I8 (White) 11571919=Thin White Blade
Baffle (I8)
BAFFLE 4FT I8=Thin White Blade Baffle (I8)
90801PPK=Asymmetrical Directional Louver
No. of
Ballast
1, 2 or 3
I8-332-UNV-UPL
15 lbs.
8TI8-332-UNV-UPL
30 lbs.
Catalog No.
Wt.