RSA Lighting T535 Merkblatt
Catalog #
Type
Project
COMBOLIGHT® COMBO CLASSIC RECESSED
LAMP GROUP 2 - CONFIGURATION “E”
TWO (2) T4 G8.5 Metal Halide lamp cells - TWO (2) Fluorescent lamp cells
New Construction Recessed Housing - Trim or Trimless
TWO (2) T4 G8.5 Metal Halide lamp cells - TWO (2) Fluorescent lamp cells
New Construction Recessed Housing - Trim or Trimless
ORDERING EXAMPLE:
= Two T4 G8.5 Metal Halide 35W lamps with Two BIAX® 40W Fluorescent • Black Interior • White Trim • 27º reflector • 120 volts
Fluorescent >> BX40
BX50
PLL80 PLT26
PLT32
PLT42
T528
T535
T5HO39 T5HO54
Lamp Group 2
Metal Halide
A
65.18” 65.18” 65.18” 30.18” 31.18” 33.18” 112.18” 136.18”
88.18”
112.18”
B
81.98” 81.98” 81.98” 46.98” 47.98” 49.98” 128.98” 152.98” 104.48”
128.98
C
25.50” 25.50” 25.50”
8.00”
8.50”
9.50”
49.00” 61.00”
37.00”
49.00”
RSA
LIGHTING
®
RSA LIGHTING LLC 9660 - 9700 TOPANGA CANYON BLVD. CHATSWORTH CA. 91311
TOLL FREE: 800-356-3030 • 818-349-3030 • FAX: 818-349-3031 • www.rsalighting.com
©2003 RSA Lighting LLC All Rights Reserved • Specifications subject to change without notice.
380º x 45º locking
angular adjustment
45º visual cut-off
angular adjustment
45º visual cut-off
Dual Fluorescent lamp cells
w/ integral ballast accessible from below
w/ integral ballast accessible from below
Integral reflector
Integral reflector
Butterfly
Brackets
for Black Iron
Mounting
Brackets
for Black Iron
Mounting
Thermal Protector
0.75" Trim
6.90"
7.00"
9.50"
8.75"
6.90"
B
A
C
C
Ceiling compund
is applied right
to the edge of the
fixture opening
is applied right
to the edge of the
fixture opening
TRIMLESS D
ET
A
IL
TR
IM
DETAIL
Must specify a diffuser or louver
for fluorescent cell. See below.
Ballast
Ballast
Aromat®
Electronic
Metal Halide
Ballasts
Electronic
Metal Halide
Ballasts
Optional Accessories - See RSA Combo Classic accessory page for details.
Baffle
Snoots
Louvers
Lenses
Fluorescent Diffusers and Louvers - Please specify
❑ TWD - Textured White Diffuser
❑ CB1 - 2” Parabolic Louver
❑ MPD - Conical Prism Diffuser
❑ CB2 - 1” Parabolic Louver
DESCRIPTION:
An adjustable recessed fixture
suitable for multiple downlighting
applications with one point of elec-
trical entry. Mixes the use of metal
halide lamps with fluorescent
lamps. Powder coat finish on hous-
ing & lamp assembly.
An adjustable recessed fixture
suitable for multiple downlighting
applications with one point of elec-
trical entry. Mixes the use of metal
halide lamps with fluorescent
lamps. Powder coat finish on hous-
ing & lamp assembly.
CONSTRUCTION:
Housing, Plaster Frame & Trim
Assembly: 18 gauge CRS. J-Box
Assembly: 16 gauge CRS (galva-
nized). Fixture is offered with a .75”
ceiling trim or as a trimless fixture.
Can accommodate 0.50” to 1.00”
ceiling thickness.
Housing, Plaster Frame & Trim
Assembly: 18 gauge CRS. J-Box
Assembly: 16 gauge CRS (galva-
nized). Fixture is offered with a .75”
ceiling trim or as a trimless fixture.
Can accommodate 0.50” to 1.00”
ceiling thickness.
LAMP ASSEMBLY:
Two T4 G8.5 Metal Halide lamp
cells with two fluorescent lamp
cells . Can accept up to two optical
accessories. 380º x 45º locking
lamp adjustment. Provides 45º
visual cut-off. Utilizes a sophisti-
cated all aluminum reflector with
distributions of 15º, 27º and 55º
spreads.
Two T4 G8.5 Metal Halide lamp
cells with two fluorescent lamp
cells . Can accept up to two optical
accessories. 380º x 45º locking
lamp adjustment. Provides 45º
visual cut-off. Utilizes a sophisti-
cated all aluminum reflector with
distributions of 15º, 27º and 55º
spreads.
SYSTEM PROTECTION:
Thermal protection provided to
guard against overheating, and
misuse of insulation over and
around fixture. Vent holes in hous-
ing provide cooler operation
Thermal protection provided to
guard against overheating, and
misuse of insulation over and
around fixture. Vent holes in hous-
ing provide cooler operation
ELECTRICAL:
Fixture is two circuit.
Circuit 1: Integral Aromat® elec-
tronic metal halide ballasts for
T4 G8.5 metal halide lamps.
Fixture is two circuit.
Circuit 1: Integral Aromat® elec-
tronic metal halide ballasts for
T4 G8.5 metal halide lamps.
Circuit 2: Integral electronic bal-
lasts for fluorescent lamps.
Lutron® dimming ballasts avail-
able upon request.
lasts for fluorescent lamps.
Lutron® dimming ballasts avail-
able upon request.
Junction box is UL listed for
through branch wiring, for 8 #12,
90°C supply conductors or 60°C for
end of run (access above ceiling
not required).
through branch wiring, for 8 #12,
90°C supply conductors or 60°C for
end of run (access above ceiling
not required).
SPECIFY -
E
Item # / Lamp Type
Configuration
Fluorescent Lamp
Interior Finish Trim Finish
Distribution
Voltage
Lamp
Group 2
Metal
Halide
Group 2
Metal
Halide
CR2TC35 - T4 G8.5 MH 35W E - Two T4 G8.5
Metal Halide
lamp cells with
Two Fluorescent
lamp cells
lamp cells with
Two Fluorescent
lamp cells
BX40 - 40W BIAX®
BK - Black
BK - Black
15 - 15º Narrow Reflector 120 - 120 Volts
CR2TC70 - T4 G8.5 MH 70W
BX50 - 50W BIAX®
WH - White
WH - White
27 - 27º Medium Reflector 277 - 277 Volts
PLL80 - 80W PL-L
S - Silver
S - Silver
55 - 55º Wide Reflector
PLT26 - 26W PL-T
PT - Custom
PT - Custom
PLT32 - 32W PL-T
TR - Trimless
PLT42 - 42W PL-T
T528 - 28W T5
T535 - 35W T5
T5HO39 - 39W T5HO
T5HO54 - 54W T5HO
T528 - 28W T5
T535 - 35W T5
T5HO39 - 39W T5HO
T5HO54 - 54W T5HO
T8 lamps also available
CR2TC35
E
BX40
BK
WH
27
120
Custom configurations are available
with Combo Classic fixtures. Also
available with T8 fluorescent lamps.
Consult RSA for details
with Combo Classic fixtures. Also
available with T8 fluorescent lamps.
Consult RSA for details
Luminance / Performance Comparison to Regular H.I.D. Lamps
Regular MH Lamp
T4 G8.5 MH Lamp
Initial Lumens
35W = 2000
70W = 4850
35W = 3300
70W = 6600
Rated Lamp Life 35W = 9000 hrs 70W = 9000 hrs 35W = 9000 hrs 70W = 9000 hrs
___
___
___
___
___
___