Magenta XR2000 Benutzerhandbuch

Seite von 24
18 
MAGENTA MULTIVIEW™ SERIES 
16 
Appendix C. Setting Sync Mode 
 
The XR2000 has the  capability for fixed and agile sync. The default sync mode setting 
is for agile sync which  replicates the source sync polarity signals. However some 
displays require a fixed sync polarity that is not possible to change at the video source. 
The following details jumper settings to change the sync polarity of the horizontal and 
vertical sync signals (Note that jumpers JP11 and JP12 have no affect in agile mode): 
 
 
 
 
 
 
 
 
 
 
Sync Mode jumpers 
JP10, JP11, JP12
 
Jumper Setting 
JP10 
JP11 
JP12 
Fixed Sync 
IN 
Agile Sync (default) 
OUT 
Horizontal Sync 
Positive 
IN 
  Horizontal Sync 
Negative 
OUT 
  Vertical Sync 
Negative 
IN 
  Vertical Sync 
Negative 
OUT