Runco RS-900 Series RS1100 Series Betriebsanweisung

Seite von 104
64
RS-900 and RS1100 Series Installation/Operation Manual
PRE
L
IMINAR
Y
RVR: Use the RVR control to increase or decrease the Reflectance Volume Regulation 
setting. RVR lets you control the aperture or iris size (the physical opening through the 
lens; similar to an “f-stop” on a camera). Doing so allows you to optimize brightness and 
contrast according to the amount of ambient light in the viewing area. 
Use a higher setting for rooms with a lot of ambient light. Use a lower setting for more 
“theater-like” viewing conditions (little or no ambient light). 
12-volt TriggerSelect 12-volt Trigger from the Setup menu to configure the 12-volt 
trigger output. 
• Set the 12-volt Trigger to Normal if you want the trigger to activate when the projector 
is turned on (for instance, if the trigger is controlling a retractable screen). 
• Set  the  12-volt Trigger to Cinema if you want the trigger to activate when the Cinema or 
Virtual Cinema aspect ratio is selected. Choose this setting if your RS-900/RS1100 is 
equipped with the Runco CineWide with AutoScope system. 
V. Correction: To achieve the proper image geometry with the secondary anamorphic 
lens, select V. Correction from the Set Up menu. Then, use the 
 or 
 button to change 
the native aspect ratio of the display, in small increments. 
Amplitude: The Amplitude menu allows you to fine-tune the aspect ratio by compressing 
it horizontally or vertically, in small increments. This can be useful if your projector is 
equipped with an anamorphic lens.
The Horizontal control adjusts the image width while keeping the height constant. 
Similarly, the Vertical control adjusts the image height while keeping the width constant.
Auto Off: When using the RS-900/RS1100 with a computer, use the Auto Off feature to 
have the RS-900/RS1100 go into standby mode when no source signal is present on the 
current input. (A warning message appears on-screen for approximately eight seconds 
before this occurs.) Select an Auto-Off interval of from five to 30 minutes, in five-minute 
increments. To return to normal operating mode from the Auto Off standby mode, select 
the input with the remote control or operate your computer.
When Auto Off is disabled, the RS-900/RS1100 remains in normal operating mode, 
regardless of the presence or absence of an input sync signal. 
Default: To restore all Setup Menu options to their factory-default values, select Default 
and press the 
 button to highlight “Yes.” Then, press ENTER.
1. If the computer is turned off or not properly connected to the 
RS-900/RS1100, the system is set to the off state.
2. For instructions on using the computer's power management 
features, refer to the instructions for your computer. 
Note