Runco X-200i Benutzerhandbuch

Seite von 118
90
Runco X-200i Series Installation/Operation Manual
PRE
L
IMINAR
Y
cal.text1
cal.text2
cal.text3
=
Up to 30 characters. 
The X-200i start-up screen is cus-
tomizable with three lines of text of 
up to 30 characters each. This text 
appears below the “CALIBRATED 
FOR:” text in the logo screen.  The 
allowable characters are all num-
bers, letters (uppercase and low-
ercase), spaces, and symbols 
available in the ASCII code set.
3d.dlplink
= ?
0 = Off
1 = On
3d.pattern
= ?
0 = Off
1 = On
3D Test Patttern enable/disable
cec.enable
= ?
0 = Off
1 = On
HDMI CEC enable/disable
act.source
?
Query current input source
prerr
(execute)
Query the error log
hsg
= ?
00 - C8 (0 - 200 decimal) for 
each of the following, in this 
order:
Red Hue
Yellow Hue
Green Hue
Cyan Hue
Blue Hue 
Magenta Hue
Red Saturation
Yellow Saturation
Green Saturation
Cyan Saturation
Blue Saturation
Magenta Saturation
Red Level
Yellow Level
Green Level
Cyan Level
Blue Level
Magenta Level
Red Gain (White Balance)
Green Gain (White Balance)
Blue Gain (White Balance)
This command provides an alter-
native to setting the PCE Hue, 
Saturation, Level and White Bal-
ance values using individual com-
mands. 
It is only available when 
color.gamut = 6
 (PCE). 
The value string is 21 bytes (42 
characters) long. Each byte sets 
the corresponding PCE parame-
ter; refer to the list at left. 
Example: This command sets all 
PCE parameters to 100 (50%): 
hsg =  
646464646464 
646464646464 
646464646464  
646464 
(Spaces are for readability.)
Table 6-2. Serial Commands (continued)
Operation
Commands
Values
Notes