Hitachi CP-WX3014WN Benutzerhandbuch

Seite von 32
32
PJLink command (continued)
Commands
Control Description
Parameter or Response
ERST ?
Error Status inquiry
1st byte: Refers to Fan error; one of 0 to 2
2nd byte: Refers to Lamp error; one of 0 to 2
3rd byte:  Refers to Temptrature error; one of 0 to 2
4th byte: Refers to Cover error; one of 0 to 2
5th byte: Refers to Filter error; one of 0 to 2
6th byte: Refers to Other error; one of 0 to 2
The mearning of 0 to 2 is as given below
0 = Error is not detected;   
1 = Warning;     2 = Error
LAMP ?
Lamp Status inquiry
1st number (digits 1 to 5): Lamp Time
2nd number : 0 = Lamp off, 1 = Lamp on
INST ?
Input Source List inquiry
11  12  21  22  23  31  41  51  52
NAME ?
Projector Name inquiry
Responds with the name set in "PROJECTOR 
NAME" of "NETWORK"
INF1 ?
Manufucturer's Name 
inquiry
HITACHI
INF2 ?
Model Name inquiry
CP-X2514WN
CP-X3014WN
CP-X4014WN
CP-WX3014WN
INFO ?
Other Information inquiry
Responds with the factory information and so 
on
CLSS ?
Class Information inquiry
1
NOTE • The password used in PJLink
TM
 is the same as the password set in 
the Web Brouwser Comtrol. To use PJLink
TM
 without authentication, do not set 
any password in Web Browser Control.
• For specifications of PJLink
TM
, see the web site of the Japan Business 
Machine and Information System Industries Association.
URL: http://pjlink.jbmia.or.jp/ (as of Feb. 2011)