Windsor SGJ32 Benutzerhandbuch

Seite von 42
MACHINE TROUBLESHOOTING 
 SGJ32  86037680  01/03/07 
4-19 
 
PROBLEM 
CAUSE 
ERROR 
CODE 
SOLUTION 
Vacuum motor does not run, 
or runs slowly 
Recovery tank full 
 
Drain recovery tank 
 
Recovery tank float 
switch dirty 
 
Clean float switch 
 
Loose motor connection 
7700 
Check motor wires and 
connections 
 
Worn vacuum motor 
brushes 
 
Replace brushes, check 
commutator 
Poor scrubbing performance 
Debris caught in scrub 
brushes 
 
Remove debris 
 
Worn brushes or pads 
 
Replace brushes or pads 
 
Improper detergent, 
brush or pad used 
 
Contact equipment or 
application specialists 
 
Low scrub brush down 
pressure 
 
Increase brush pressure 
 
Low battery charge 
 
Charge batteries 
Little or no solution flow to the 
floor 
Solution tank empty 
 
Fill solution tank 
 
Solution flow turned off 
or set too low 
 
Turn on or increase flow 
setting 
 
Solution strainer plugged
 
Clean solution strainer 
 
Solution system 
plumbing obstructed 
 
Clear obstruction from 
plumbing 
 
Solution solenoid valve 
obstructed or stuck 
 
Clean or replace valve 
 
Vent hole in solution 
tank lid obstructed 
 
Clear obstruction from vent 
hole 
 
Faulty solenoid valve 
connection 
 
Check wiring to solution valve 
Brush motors do not run, or 
run slowly 
Circuit breaker(s) tripped 
7600 
Reset circuit breaker(s) 
 
Low battery charge 
 
Charge battery 
 
Loose connection 
7600 
Check motor wires and 
connection 
 
Worn brush motor 
brushes 
 
Replace brushes, check 
commutator 
Scrub deck will not go 
down/up 
Faulty actuator 
9000 
Repair/replace actuator 
 
Loose connection 
9000 
Check motor wires and 
connections 
Scrub deck goes down, then 
raises 
No brushes or pad 
drivers on machine 
9000 
Install brushes or pad drivers 
Error code not listed is 
displayed 
Controller detects 
electrical problem 
 
Contact service technician