A.O. Smith FMV-50 Benutzerhandbuch

Seite von 32
14
Connecting  the  gas  piping  to  the  gas  control  valve  of  the  water 
heater can be accomplished by either of the two methods shown in  
Figures 9 and 10. 
sedIMent traps
A sediment trap shall be installed as close to the inlet of the water 
heater  as  practical  at  the  time  of  water  heater  installation. The 
sediment trap shall be either a tee fitting with a capped nipple in the 
bottom outlet or other device recognized as an effective sediment 
trap. If a tee fitting  is used, it shall be installed in conformance with 
one of the methods of installation shown in Figures 9,10 and 11. 
fIGure 9.  Gas pIpInG wIth fleXIBle connector.
fIGure 10.  Gas pIpInG wIth all
BlacK Iron pIpe to Gas control.
alternatIve sedIMent trap locatIon
fIGure 11. 
Contaminants in the gas lines may cause improper operation of the 
gas control valve that may result in fire or explosion.  Before attaching 
the gas line be sure that all gas pipe is clean on the inside. To trap any 
dirt or foreign material in the gas supply line, a drip leg (sometimes 
called a sediment trap) must be incorporated in the piping. The drip 
leg must be readily accessible. Install in accordance with the “Gas 
Piping” section. Refer to the current edition of the National Fuel Gas 
Code, ANSI Z223.1/NFPA 54. 
whIte-rodGers fuel conversIon 
InstructIons froM natural Gas to 
propane (l.p.) Gas
Fuel  conversions  shall  be  completed  by  a  qualified  service 
agency  in  accordance  with  the  detailed  conversion  instructions 
and all applicable codes and requirements of the authority having 
jurisdiction. The information in these instructions must be followed to 
minimize the risk of fire or explosion and to prevent property damage, 
personal injury or death. The qualified service agency is responsible 
for the proper installation of this kit. The installation is not proper and 
complete until the operation of the appliance is checked as specified 
in the manufacturer’s instructions.
1.  Read and follow detailed conversion instructions below and also 
on the heater.
2.  The conversion kit with necessary parts are in a bag attached to 
the side of the water heater.
3.  Shut off the gas supply to the water heater.
4.  Remove the outer door.
5.  Rotate  the  thermostat  dial  on  the  water  heater  control 
counterclockwise (
) until the main burner ignites and burns 
off all residual gas in the control and supply lines.
6.  Rotate the thermostat dial clockwise ( ) back to the “PILOT 
LIGHTING” position.
7.  Turn the gas control knob “A” to “PILOT”. Depress knob slightly 
and rotate to “OFF” position, see Figure 12.
fIGure 12. 
8.  Unplug wire from igniter assembly mounted to the top of the gas 
valve.