InstallatIon checKlIst
Before lIGhtInG the pIlot:
1.  Check the gas lines for leaks.
 
a.  Use  a  soapy  water  solution.  DO  NOT  test  for  gas  leaks 
using a match or open flame.
 
b.  Brush the soapy water solution on all gas pipes, joints and 
fittings.
 
c.  Check for bubbling soap. This means you have leak. Turn 
“OFF” gas and make the necessary repairs.
2.  Is the new temperature-pressure relief valve properly installed 
and piped to an adequate drain? See “Temperature-Pressure 
Relief Valve” section.
3.  Are the cold and hot water lines connected to the water heater 
correctly? See “Water Piping” instructions in the “Installing the 
New Water Heater” section.
4.  Is the water heater completely filled with water? See “Filling 
the Water Heater” instructions in the “Installing the New Water 
Heater” section.
5.  Will a water leak damage anything? See the “Locating the New 
Water Heater” section.
6.  Is  there  proper  clearance  between  the  water  heater  and 
anything  that  might  catch  fire?  See  the  “Locating  the  New 
Water Heater” section.
7.  Do you have adequate ventilation so that the water heater will 
operate properly? See the “Locating the New Water Heater” 
section.
8.  Is the draft hood vent piping properly secured? See “Venting” 
instructions in the “Installing the New Water Heater” section.
9.  Is there proper clearance between the vent pipe and anything 
that  might  catch  on  fire?  See  “Venting”  Instructions  in  the 
“Installing the New Water Heater” section.
10.  Is the vent pipe properly sloped and does the vent terminate 
outdoors? See “Venting” instructions in the “Installing the New 
Water Heater” section.
11.  Do you need to call your gas company to check the gas pipe 
and its hookup?