leaKaGe checKpoInts
Read this manual first.  Then before checking the water heater make 
sure the gas supply has been turned “OFF”, and never turn the gas 
“ON” before the tank is completely full of water.
A.  Water at the draft hood is water vapor which has condensed out 
of the combustion products.  This is caused by a problem in the 
vent.  Contact the gas utility.
B.  *Condensation may be seen on pipes in humid weather or pipe 
connections may be leaking.
C.  *The anode rod fitting may be leaking.
D.  Small amounts of water from temperature-pressure relief valve 
may be due to thermal expansion or high water pressure in your 
area.
E.  *The  temperature-pressure  relief  valve  may  be  leaking  at  the 
tank fitting.
F.  Water from a drain valve may be due to the valve being slightly 
opened.
G.  *The drain valve may be leaking at the tank fitting.
H.  Combustion products contain water vapor which can condense 
on the cooler surfaces of the tank.  Droplets form and drip onto 
the burner or run on the floor.  This is common at the time of 
start-up after installation and when incoming water is cold.
I.   Water in the water heater bottom or on the floor may be from 
condensation, loose connections, or the relief valve.  DO NOT 
replace the water heater until a full inspection of all possible water 
sources is made and necessary corrective steps taken.
Leakage  from  other  appliances,  water  lines,  or  ground  seepage 
should also be checked.
*  To  check  where  threaded  portion  enters  tank,  insert  cotton 
swab between jacket opening and fitting.  If cotton is wet, follow 
“Draining” instructions in the “Periodic Maintenance” section and 
then remove fitting.  Put pipe dope or Teflon tape on the threads 
and replace.  Then follow “Filling the Water Heater” instructions 
in the “Installing the New Water Heater” section.