PRESSURE SWITCH REMOVAL / REPLACEMENT
Important: Use only factory authorized replacement 
parts.  If you lack the necessary skills to properly 
perform the installation, you should not proceed, but 
get help from a qualified service technician.
Tools required: Phillips Head Screwdriver.
Removing the Pressure Switch:
1.  Set the gas control valve/thermostat to its lowest 
setting by pressing the “COOLER” and “HOTTER” 
buttons together at the same time holding for 1 
second. Then press the “COOLER” button to the 
lowest setting (Figure 36).
2.  Turn gas control switch to the “OFF” position 
(located right side of the gas control valve/
thermostat) and turn off the gas supply to the unit 
(Figure 37). 
3.  Disconnect the electric connection by unplugging 
the transformer from the wall outlet (Figure 37).
4.  Remove the manifold cover/ outer door from the 
unit by depressing on the lower portion and pulling 
outward.
5.  Remove the air pressure tubing from the air 
pressure switch by pulling downward on the 
tubing at the connection to the air pressure switch 
(Figure 38).
6.  Remove the two (2) electrical flag terminals from 
the switch by pulling outward and off of the switch 
(Figure 39).
7.  Using a phillips head screwdriver, remove the 2 
screws securing the pressure switch to the water 
heater’s side (keep these screws in a safe place 
for reinstallation later) (Figure 39).
Installing the Pressure Switch:
8.  Secure the new pressure switch to the water 
heater’s side by reusing the 2 screws removed in 
step 7 (Figure 39).
9.   Reattach the two (2) electrical flag terminals 
by pushing the flag terminals onto the switch    
(Figure 39).
10. Reattach the air pressure tubing to the air 
pressure switch by pushing the tubing onto the 
connector until the end of the tubing pushes to the 
shoulder of the connector (Figure 38).
11. Turn on the electrical and the gas supplies to the 
water heater. Plug in the electric connection from 
the transformer to the electric outlet (Figure 37).
12. Restart the water heater by following the 
directions on the “Lighting and Operating 
Instructions” label located on the front of the water 
heater.
13. Upon verifying proper operation of the water 
heater, replace the manifold cover/outer door.
Figure 39.
SCREW
AIR PRESSURE
     TUBING
    FLAG
TERMINALS
PRESSURE
  SWITCH
g
COOLER
HOTTER
Electronic Control Display
Figure 36.
PRESSURE SWITCH
TUBING CONNECTION
Figure 38.
ON/OFF 
SWITCH
ON
OFF
Figure 37.
UNPLUGGED