PRESSURE TUBING REMOVAL / REPLACEMENT
Important: Use only factory authorized replacement 
parts.  If you lack the necessary skills to properly 
perform the installation, you should not proceed, but 
get help from a qualified service technician.
Tools required: Phillips Head Screwdriver.
Removing the Air Intake Chamber Box:
1.  Set the gas control valve/thermostat to its lowest 
setting by pressing the “COOLER” and “HOTTER” 
buttons together at the same time holding for 1 
second. Then press the “COOLER” button to the 
lowest setting (Figure 74).
2.  Turn gas control switch  to the “OFF” position 
(located right side of the gas control valve/
thermostat) and turn off the gas supply to the unit 
(Figure 75). 
3.  Disconnect the electric connection by unplugging 
the transformer from the wall outlet (Figure 75).
4.  Remove the manifold cover/ outer door from the 
unit by depressing on the lower portion and pulling 
outward.
5.  Remove the air pressure tubing from the air 
pressure switch by pulling downward on the 
tubing at the connection to the air pressure switch 
(Figure 76).
6.  Using a phillips head screwdriver, remove the 4 
screws securing the air intake chamber box to the 
water heater’s side (Note: keep these screws in a 
safe place for reinstallation later) (Figure 77).
7.  Rotate the top of the air intake chamber box from 
left to right (only a few inches in both directions) 
while pulling outward at the bottom removing 
the air intake chamber box from the combustion 
chamber pipe saving the air intake chamber 
gasket for reinstallation (Figure 77).
8.  Upon removal of the air intake chamber box, 
locate the air pressure tubing at the back of the air 
intake chamber box and unplug the tubing. Note 
the routing of the air pressure tubing through the 
water heater’s opening near the bottom. Remove 
the old air pressure tubing (Figures 76 & 77).
9.   Connect the new air pressure tubing into the back 
of the air intake chamber box by pushing it on the 
connector (Figure 78).
10. Route the new air pressure tubing through the 
water heater’s opening near the bottom (Note: 
mirrors the position of the old tubing) (Figures 77).
Figure 76.
PRESSURE SWITCH
TUBING CONNECTION
Figure 77.
CHAMBER GASKET
ROTATE FROM 
LEFT TO RIGHT
          AND  
  
PULL OUTWARD
SCREWS
AIR PRESSURE
     TUBING
g
COOLER
HOTTER
Electronic Control Display
Figure 74.
ON/OFF 
SWITCH
ON
OFF
Figure 75.
UNPLUGGED