Instruction manual BFC
17
is
3
Installation
Warning
Installation work should be carried out by an approved installation engineer 
in compliance with the general and local regulations imposed by the gas, water 
and power supply companies and the fire service.
The appliance may only be installed in a room that complies with the 
requirements stated in national and local ventilation 
regulations
.
3.1
Introduction
This chapter describes the installation activities to be carried out before you 
actually start using the appliance
, namely:
;
;
;
In the event of conversion to a different gas category, see 
conversion
.
3.2
Packaging
To avoid damaging the appliance, remove the packaging carefully.
We recommend unpacking the appliance at or near its intended location.
Caution
The appliance may only be manoeuvred in an upright position. Take care 
that the appliance is not damaged after unpacking.
3.3
Environmental 
conditions
The appliance is suitable for either open or room-sealed combustion. If 
installed as a room-sealed appliance, then the availability of the necessary 
external air supply will depend on the place of installation. In this event, there 
are no additional ventilation requirements. 
If the appliance is to be installed as an open system, then it will be subject to 
the guidelines and ventilation regulations that are in force locally.
The alternative installation types are B23, C13, C33, C43, C53 and C63.
Caution
The appliance may not be used in rooms where chemical substances are 
stored or used, due to the risk of explosion and/or corrosion of the appliance. 
Some propellants, bleaching agents, degreasing agents etc. disperse vapours 
which are explosive and/or which cause accelerated corrosion. If the appliance 
is used in a room in which such substances are present, the warranty will be 
void.