A.O. Smith BTI - 65 Benutzerhandbuch

Seite von 6
BTI
Technical specifications
Gas data natural gas 2H (G20)        
Input* 
kW 
18.1 
23.1 
27.4
Output 
kW 
12.7 
16.2 
19.2
Inlet pressure 
mbar 
20 
20 
20
Burner pressure 
mbar 
12 
11,5 
10
Gas consumption** 
m
3
/h 
1.7 
2,2 
2.6
Diameter pilot orifice 
mm 
0.56/0.41 
0.56/0.41 
0.56/0.41
Diameter main orifice 
mm 
3.4 
3,9 
4.5
Max. flue gas temperature 
°C 
265 
275 
275
Flue gas discharge 
kg/h 
27 
55.2 
53.2
                          
Gas data butane 3+ (G30)                         
Input* 
kW 
17.2 
21.8 
29.6
Output 
kW 
12.3 
15.7 
21.2
Inlet pressure 
mbar 
30 
30 
30
Burner pressure 
mbar 
-
Gas consumption** 
kg/h 
1.3 
1.6 
2.2
Diameter pilot orifice 
mm 
0.23 
0.23 
0.23
Diameter main orifice 
mm 
1.9 
2.2 
2.5
Max. flue gas temperature 
°C 
265 
275 
275
Flue gas discharge 
kg/h 
81.1 
74.8
                          
Gas data propane 3+ (G31)                         
Input* 
kW 
16.4 
20.9 
28.6
Output 
kW 
11.7 
15 
20.4
Inlet pressure 
mbar 
37 
37 
37
Burner pressure 
mbar 
-
Gas consumption** 
kg/h 
1.2 
1,5 
2,0   
Diameter pilot orifice 
mm 
0.23 
0.23 
0.23
Diameter main orifice 
mm 
1.9 
2.2 
2.5
Max. flue gas temperature 
°C 
265 
275 
275
                          
Draw-off capacity                       
Storage capacity 
178 
265 
355
Max. temperature setting 
°C 
80 
80 
80
30 min. ∆T=44°C 
281 
396 
508
60 min. ∆T=44°C 
405 
554 
713
90 min. ∆T=44°C 
529 
713 
871
120 min. ∆T=44°C 
652 
871 
1070
Continuous ∆T=44°C 
l/h 
247 
375 
399
Heating-up time ∆T=44°C 
min. 
43 
42 
53
30 min. ∆T=50°C 
248 
348 
447
60 min. ∆T=50°C 
356 
488 
612
90 min. ∆T=50°C 
465 
627 
777
120 min. ∆T=50°C 
574 
767 
992
Continuous ∆T=50°C 
l/h 
218 
330 
351
Heating-up time ∆T=50°C 
min. 
49 
48 
61
30 min. ∆T=55°C 
225 
317 
406
60 min. ∆T=55°C 
324 
443 
556
90 min. ∆T=55°C 
423 
570 
706
120 min. ∆T=55°C 
522 
697 
856
Continuous ∆T=55°C 
l/h 
198 
300 
319
Heating-up time ∆T=55°C 
min. 
54 
53 
67
                          
Electrical data                         
Power consumption 
 
30 
Power supply 
VAC/Hz 
                                
 230(-15/+10%) / 50 
General                         
Anodes 
 
Maximum working pressure 
bar 
 
Maximum weight 
kg 
266 
382 
499 
 
 
 
 
Shipping data                         
Weight empty 
kg 
93 
122 
149
Weight incl. packaging BTT / BTI 
kg 
105 
140 
167
Width packaging 
mm 
670 
780 
780
Height packaging 
mm 
1690 
1640 
1830
Depth packaging 
mm 
730 
870 
870
BTI 65
BTI 85
BTI 100
Gas data on gross value
 
**
 Gas consumption at 15°C and 1013.25 mbar