Fit pipe insulation over the incoming cold water line and the hot 
water line. Make sure that the insulation is against the top cover of 
the heater.Fit T & P valve insulation over valve. Make sure that the 
insulation does not interfere with the lever of the T & P valve.
Secure all insulation using tape.
teMperature-pressure relIef valve
Explosion Hazard
Temperature-Pressure Relief Valve
must comply with ANSI Z21.22-
CSA 4.4 and ASME code.
Properly sized temperature-
pressure relief valve must be
installed in opening provided.
Can result in overheating and
excessive tank pressure.
Can cause serious injury or death.
This  water  heater  is  provided  with  a  properly  rated/sized  and 
certified  combination  Temperature-Pressure  Relief  Valve  (T&P 
valve) by the manufacturer. The valve is certified by a nationally 
recognized testing laboratory that maintains periodic inspection 
of  production  of  listed  equipment  of  materials  as  meeting  the 
requirements  for  Relief  Valves  for  Hot  Water  Supply  Systems, 
ANSI Z21.22 • CSA 4.4, and the code requirements of ASME.
If  replaced,  the  new  T&P  valve  must  meet  the  requirements 
of  local  codes,  but  not  less  than  a  combination  Temperature-
Pressure  Relief  Valve  rated/sized  and  certified  as  indicated  in 
the  above  paragraph.  The  new  valve  must  be  marked  with  a 
maximum  set  pressure  not  to  exceed  the  marked  hydrostatic 
working pressure of the water heater (150 psi = 1,035 kPa) and 
a discharge capacity not less than the water heater Btu/hr or kW 
input rate as shown on the water heater’s model rating plate.
note: In addition to the factory installed Temperature-Pressure 
Relief  Valve  on  the  water  heater,  each  remote  storage  tank 
that  may  be  installed  and  piped  to  a  water  heating  appliance 
must  also  have  its  own  properly  sized,  rated  and  approved 
Temperature-Pressure  Relief  valve  installed.  Call  the  toll  free 
technical  support  phone  number  listed  on  the  back  cover  of 
this  manual  for  technical  assistance  in  sizing  a  Temperature-
Pressure Relief valve for remote storage tanks.
For  safe  operation  of  the  water  heater,  the  Temperature-
Pressure Relief valve must not be removed from its designated 
opening  nor  plugged.  The  Temperature-Pressure  Relief  valve 
must  be  installed  directly  into  the  fitting  of  the  water  heater 
designed for the relief valve. Install discharge piping so that any 
discharge will exit the pipe within 6 inches (15.2 cm) above an 
adequate floor drain, or external to the building. In cold climates 
it  is  recommended  that  it  be  terminated  at  an  adequate  drain 
inside the building. Be certain that no contact is made with any 
live electrical part. The discharge opening must not be blocked 
or reduced in size under any circumstances. Excessive length, 
over 30 feet (9.14 m), or use of more than four elbows can cause 
restriction and reduce the discharge capacity of the valve.
No  valve  or  other  obstruction  is  to  be  placed  between  the 
Temperature-Pressure Relief Valve and the tank. Do not connect 
discharge piping directly to the drain unless a 6” (15.2 cm) air gap is 
provided. To prevent bodily injury, hazard to life, or property damage, 
the  relief  valve  must  be  allowed  to  discharge  water  in  adequate 
quantities should circumstances demand. If the discharge pipe is 
not connected to a drain or other suitable means, the water flow 
may cause property damage.
Water Damage Hazard
Temperature-Pressure Relief Valve discharge
pipe must terminate at adequate drain.
CAUTION
t&p valve dIscharGe pIpe requIreMents:
•  Shall not be smaller in size than the outlet pipe size of the valve, 
or have any reducing couplings or other restrictions.
•  Shall not be plugged or blocked.
•  Shall not be exposed to freezing temperatures.
•  Shall be of material listed for hot water distribution.
•  Shall be installed so as to allow complete drainage of both the 
Temperature-Pressure Relief Valve and the discharge pipe.
•  Must terminate a maximum of six inches above a floor drain or 
external to the building. In cold climates, it is recommended that 
the discharge pipe be terminated at an adequate drain inside 
the building.
•  Shall not have any valve or other obstruction between the relief 
valve and the drain.
Burn hazard.
Hot water discharge.
Keep clear of Temperature-
Pressure Relief Valve
discharge outlet.
The  Temperature-Pressure  Relief  valve  must  be  manually 
operated  at  least  twice  a  year.  Caution  should  be  taken  to 
ensure that (1) no one is in front of or around the outlet of the 
Temperature-Pressure  Relief  Valve  discharge  line,  and  (2) 
the  water  manually  discharged  will  not  cause  any  bodily  injury 
or  property  damage  because  the  water  may  be  extremely  hot. 
If after manually operating the valve, it fails to completely reset 
and continues to release water, immediately close the cold water 
inlet  to  the  water  heater,  follow  the  draining  instructions  in  this 
manual, and replace the Temperature-Pressure Relief Valve with 
a properly rated/sized new one.
note: The purpose of a Temperature-Pressure Relief valve is to 
prevent excessive temperatures and pressures in the storage tank. 
The  T&P  valve  is  not  intended  for  the  constant  relief  of  thermal 
expansion. A properly sized thermal expansion tank must be installed 
on  all  closed  systems  to  control  thermal  expansion,  see  Closed 
Water Systems and Thermal Expansion on pages 15 and 16.
If you do not understand these instructions or have any questions 
regarding  the  Temperature-Pressure  Relief  Valve  call  the  toll 
free number listed on the back cover of this manual for technical 
assistance.