A.O. Smith 100 Power Vent DV Series 120 Benutzerhandbuch

Seite von 60
54
fault and alert MessaGes
Call the technical support phone number listed on the back cover for further technical assistance or to locate a qualified service agent in 
your area.
possIble causes - checK/repaIr
dIsplaYed fault/alert MessaGe
The water heater’s control system is polarity sensitive and will lock 
• 
out and disable heating operation if the polarity of the power supply 
is reversed. The control system will display the “AC Reversed” 
Fault message on the LCD in this condition.
note: Electronic flame sensing requires correct power supply 
polarity AND a proper earth ground to the water heater and the 
Main Burner. The control system does not verify earth ground 
but this should be checked first if ignition failure occurs. See the 
Ignition Failure Fault message information below.
 
CHANGE
 
BACK 
ADVANCED
AC Reversed
Fault occurred 2 mins ago
Power supply to water heater
has reversed polarity.
Call a service professional:
Your Company Name Here
(press [DOWN] for more....)
The control system has failed to ignite the Main Burner.
• 
Water heater is not properly grounded, loose or open ground wire 
• 
to the Main Burner.
Dirty/corroded flame sensor, clean flame sensor with fine steel 
• 
wool (replace if damaged).
Loose or open wiring to the flame sensor.
• 
Loose or open wiring to the 24 V Gas Valve.
• 
Supply gas turned off, low gas volume.
• 
Intake air and/or vent piping is restricted or improperly installed.
• 
Low or no manifold gas pressure to the Main Burner.
• 
 
CHANGE
 
BACK 
ADVANCED
Ignition Failure
Fault occurred 2 mins ago
The water heater has failed to
ignite the burner.
Call a service professional:
Your Company Name Here
(press [DOWN] for more....)
The control system has detected low current (AC amps) from the 
• 
Hot Surface Igniter. The control system monitors igniter current 
and will declare this Fault condition if the current is not at or above 
the programmed minimum requirement.
Loose or open wiring to the Hot Surface Igniter.
• 
Damaged, worn or open circuit Hot Surface Igniter.
• 
note: Hot surface igniters are wearing parts. Wear is directly 
related to heating cycle count. Heating cycle count can be viewed 
in the Heater Information menu. Increasing the Differential setting 
reduces heating cycle count.
 
CHANGE
 
BACK 
ADVANCED
Low Igniter Current
Fault occurred 2 mins ago
Igniter current is low.
Call a service professional:
Your Company Name Here
(press [DOWN] for more....)
The control system has detected the Blocked Exhaust Switch 
• 
contacts are open.
The condensate drain is blocked filling the exhaust elbow with 
• 
water - clear the condensate drain.
Loose or open wiring to the Blocked Exhaust Switch.
• 
Restricted/blocked vent piping - condensate trapped in low point.
• 
Excessive equivalent pipe length, exceeded the maximum number 
• 
of 90° elbows or wrong pipe size used in the vent piping system.
Excessive wind outdoors pressurizing the vent system piping.
• 
Excessive negative air pressure in the installed space.
• 
 
CHANGE
 
BACK 
ADVANCED
Blocked Exhaust
Fault occurred 2 mins ago
The exhaust is blocked or
restricted. Ensure
condensate hose is draining.
Call a service professional:
Your Company Name Here
(press [DOWN] for more....)