Converting the Lower Element
These instructions only cover the conversion of the convertible 
element,  read  this  entire  manual  before  attempting  to  install 
or operate the water heater. The water heater is factory set to 
operate at 3800 watts. The lower element can be converted to 
operate at 5500 watts. Refer to “Facts to Consider About the 
Convertible Lower Element” section.
The Upper Element, (if double element model) is a conventional 
3800 watt element which only operates at its rated wattage on 
240 volts. (See rating plate on the water heater.
The lower Element of the water heater can be converted from 
operation at 3800 watts to 5500 watts on a 240 volt system.
If after reading these instructions and this manual, if you do not 
understand any portion call Sears Service Center.
before making the conversion to 5500 watts, check the (1) power 
supply . . . must be 240 volts, (2) wiring . . . 10 gauge AWG @ 
Type TW, 60°C or equivalent, and (3) Circuit breakers or fusing . 
. .capable of 30 amp loading. Also, the installation must conform 
with this manual, local codes and electric utility rules. Failure to 
comply can result in DEATH, SERIOUS bODILy INjURy, OR 
PROPERTy DAMAGE.
NOTE:  Whether  or  not  the  element  conversion  is  made  the 
model rating plate must be marked. Using a hard point ink pen, 
check the appropriate block within the model rating plate, which 
is located adjacent to the lower access panel.
FIGURE 11.
Necessary element conversion parts are located in a small bag 
contained within the electrical junction box on top of the water 
heater.
FIGURE 12.
1.  before beginning the conversion turn “OFF” electric power 
supply to the water heater.
FIGURE 13.
2.  The convertible element is located behind the lower access 
panel of the water heater. Remove the two screws securing 
the access panel, and remove panel.
        
FIGURE 14.
3.  Remove  the  insulation  cap  with  handle  to  expose  the 
terminal cover.
FIGURE 15.
4.  Lower Element: Lift out the tab as shown to unclip the terminal 
cover from the thermostat. The terminal cover can now be 
removed from the thermostat.