LEAKAGE CHECKPOINTS
Read this manual first. Then before checking the water heater 
make sure the electric supply has been turned “OFF”, and never 
turn the electric supply “on” before the tank is completely full of 
water.
Use this guide to check a “Leaking” water heater. Many suspected 
“Leakers” are not leaking tanks. Often the source of the water 
can be found and corrected.
If you are not thoroughly familiar with electric codes, the water 
heater, and safety practices, contact your local Sears Service 
Center to check the water heater.
Never use this water heater unless it is completely full of water. 
To prevent damage to the tank and heating element, the tank 
must be filled with water. The water must flow from the hot water 
faucet before turning “ON” power.
A  *Condensation may be seen on pipes in humid weather or 
pipe connections may be leaking.
b  Small amounts of water from the temperature-pressure relief 
valve may be due to thermal expansion or high water pressure 
in your area.
C  *The temperature-pressure relief valve may be leaking at the 
tank fitting.
D  The element may be leaking at the tank fitting. 
Turn electrical power “OFF”, remove access panel and insulation 
cap with handle. If leaking around element, follow proper draining 
instructions and remove element. Reposition or replace gasket on 
element. Place element into opening and tighten securely. Then 
follow “Filling the Water Heater” instructions in the “Installation 
Instructions” section.
E  Water from drain valve may be due to the valve being opened 
slightly
F  *The drain valve may be leaking at the tank fitting.
G  Water  in the water heater bottom or on the floor may be 
from condensation, loose connections or the temperature-
pressure relief valve. DO NOT replace the water heater until 
a full inspection of all possible water sources is made and 
necessary corrective steps taken.
Leakage from other appliances, water lines, or ground seepage 
should also be checked.
Note: To check where threaded portion enters tank, 
insert cotton swab between jacket opening and fitting. 
If cotton is wet, follow “Draining” instructions in the 
“Service  and Adjustment”
  section  and  then  remove 
fitting. Put pipe dope or teflon tape on the threads 
and  replace.  Then  follow  “Filling  the  Water  Heater” 
instructions in the “Installation Instructions” section.