11.  Replace the access panel.
FIGURE 21.
12.  Complete wiring to the water heater, or if completed, turn 
“ON” electric power to the water heater after filling the tank 
with water.
FIGURE 22.
Never use this water heater unless it is completely full of water. 
To prevent damage to the tank and heating element, the tank 
must be filled with water. Water must flow from the hot water 
faucet before turning “ON” power.
Wiring 
you  must  provide  all  wiring  of  the  proper  size  outside  of  the 
water heater. you must obey local codes and electric company 
requirements when you install this wiring.
If you are not familiar with electric codes and practices, or if you 
have any doubt, even the slightest doubt, in your ability to connect 
the wiring to this water heater, obtain the service of a competent 
electrician.  Contact  your  Sears  salesperson  to  arrange  for  a 
professional electrician.
WATER  HEATERS  EQUIPPED  FOR  ONE  VOLTAGE  ONLy: 
This water heater is equipped for one type voltage only. Check 
the rating plate near the bottom access panel for the correct 
voltage. DO NOT use this water heater with any voltage other 
than the one shown on the model rating plate. Failure to use the 
correct voltage can cause problems which can result in DEATH, 
SERIOUS bODILy INjURy, OR PROPERTy DAMAGE. If you 
have any questions or doubts consult your electric company.
If wiring from your fuse box or circuit breaker box was aluminum 
for your old water heater, replace it with copper wire. If you wish 
to reuse the existing aluminum wire, have the connection at the 
water  heater  made  by  a  competent  electrician.  Contact  your 
Sears salesperson to arrange for a professional electrician.
      
1.  Provide  a  way  to  easily  shut  off  the  electric  power  when 
working  on  the  water  heater. This  could  be  with  a  circuit 
breaker  or  fuse  block  in  the  entrance  box  or  a  separate 
disconnect switch.
2.  Install and connect a circuit directly from the main fuse or 
circuit breaker box. This circuit must be the right size and 
have its own fuse or circuit breaker. Refer to the chart in the 
“Product Specifications” section for the correct size wire and 
fuse or circuit breaker.
3.  If metal conduit is used for the grounding conductor:
  a.  The grounding electrode conductor shall be of copper, 
aluminum,  or  copperclad  aluminum.  The  material 
shall  be  of  one  continuous  length  without  a  splice  or 
joint.
  b.  Rigid  metal  conduit,  intermediate  metal  conduit,  or  
electrical metallic tubing may be used for the grounding 
means if conduit or tubing is terminated in fittings approved 
for grounding.
  c.  Flexible metal conduit or flexible metallic tubing shall be 
permitted for grounding if all the following conditions are 
met:
  •  The length in any ground return path does not exceed 6 
feet.
  •  The circuit conductors contained therein are protected by 
overcurrent devices rated at 20 amperes or less.
  •  The conduit or tubing is terminated in fittings approved for 
grounding. 
For  complete  grounding  details  and  all  allowable  exceptions, 
refer to the current edition of the NEC - National Electrical Code 
NFPA 70.
4.  A standard 1/2” conduit opening has been made in the water 
heater junction box for the conduit connection.