Monessen Hearth BTU/Hr Benutzerhandbuch

Seite von 32
10                                                                                                                                                                                 
49D0090
49D0090                                                                                                                                                                                                    
11
���
���
Ventilated 
Crawl Space 
Inlet Air 
Outlet
Air
Outlet
Air
Outlet
Air
Ventilated 
Attic
To Attic 
To 
Crawl 
Space 
FRESH AIR FOR COMBUSTION AND VENTILATION 
VENTILATION AIR 
FROM INSIDE BUILDING
This fresh air would come from an adjoining 
unconfined  space.  When  ventilating  to  an 
adjoining unconfined space, you must provide 
two permanent openings: one within 12" of the 
ceiling and one within 12" of the floor on the 
wall connecting the two spaces (see options 1 
and 2, Figure 6)
. You can also remove door 
into adjoining room (see option 3, Figure 6). 
Follow the National Fuel Gas Code, NFPA 54/
ANSI Z223.1, Section 5.3, Air for Combustion 
and Ventilation
 for required size of ventilation 
grills or ducts.
VENTILATION AIR FROM OUTDOORS
Provide  extra  fresh  air  by  using  ventilation 
grills or ducts. You must provide two perma-
nent openings: one within 12" of the ceiling 
and one within 12" of the floor. Connect these 
items directly to the outdoors or spaces open to 
the outdoors. These spaces include attics and 
crawl spaces. Follow the National Fuel Gas 
Code, NFPA 54/ANSI Z223.1, Section 5.3, Air 
for  Combustion  and Ventilation  for  required 
size of ventilation grills or ducts.
IMPORTANT:  Do  not  provide  openings 
for inlet or outlet air into attic if attic has a 
thermostat-controlled power vent. Heated 
air entering the attic will activate the power 
vent.
Figure 6 - Ventilation Air from Inside Building
Figure 7 - Ventilation Air from Outdoors
Rework worksheet, adding 
the  space  of  the  adjoining 
unconfined  space.  The 
combined  spaces  must 
have  enough  fresh  air  to 
supply  all  appliances  in 
both spaces.
W
ARNING
Option 1:
Ventilation 
Grills into 
Adjoining 
Room 
Option 2:
Ventilation Grills into 
Adjoining Rooms
Option 
3:
Remove 
Door into 
Adjoining 
Room