Monessen Hearth BTU/Hr Benutzerhandbuch

Seite von 32
20                                                                                                                                                                                 
49D0090
49D0090                                                                                                                                                                                                    
21
��
��
��
OPERATING INSTRUCTIONS
1.  STOP! Read the safety information label.
2.  Make sure the manual shutoff valve is fully open.
3.  This gas log set is equipped with an ignition device (piezo) which automatically lights the pilot. If piezo 
ignitor does not light the pilot, refer to instructions for 
“Match Lighting Instructions”
, page 21.
4.  Turn gas control knob clockwise 
 to the OFF position.
5.  Wait  (5)  minutes  to  clear  out  any  gas. Then  smell  for  gas,  including  near  the  floor.  If  you  smell  gas, 
STOP! Follow the instructions under 
“What To Do if You Smell Gas,”
 page 17. If you don't smell gas, go to 
next step.
6.  From OFF position, turn the gas control knob counterclockwise 
 to PILOT position. Push in control 
knob for 5 seconds. 
See Figure 20. 
NOTE: If you are running the heater for the first time, it will be 
necessary to press in the control knob for 30 seconds or longer to allow air to bleed out 
of the gas piping. 
7.  With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached 
to the front of burner. If needed, keep pressing ignitor button until pilot lights. Note: If pilot does not 
stay lit, refer to “Troubleshooting,” pages 32 through 25. Also contact a qualified service 
person or gas supplier for repairs. Until repairs are made, light pilot with match. To light 
pilot with match, see “Match Lighting Instructions,” page 21.
8.  Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.
      •  If control knob does not pop up when released, contact a qualified service person or gas supplier for 
repairs.
        Note: If pilot goes out, repeat steps 4 through 8 . This heater has a safety interlock system. Wait 
one (1) minute before lighting pilot again.
9.  Turn  control  knob  counterclockwise  counterclockwise 
  to  desired  heating  level.  The  main 
burner should light. Set control knob to any  heat level between HI and LO. For thermostat operation, see 
page 21. 
 LIGHTING INSTRUCTIONS 
Do not try to adjust heating levels by 
using the equipment shutoff valve.
W
ARNING
Figure 18 - Control Knob In The OFF Position
Figure 19 - Pilot 
Thermocouple (LP only)
Pilot Burner
Ignitor Electrode
Control 
Knob
Piezo 
Ignitor 
Thermocouple 
(NG only)