CLEANING AND MAINTENANCE 
You must keep control areas, burner, and circulating air passageways of heater clean. 
Inspect these areas of heater before each use. Have heater inspected yearly by a qualified 
service person. Heater may need more frequent cleaning due to excessive lint from 
carpeting, pet hair, bedding material, etc.
CAUTION
Turn  off  heater  and  let  cool  before 
cleaning.
W
ARNING
CLEANING BURNER INJECTOR HOLDER AND-
PILOT AIR INLET HOLE
The primary air inlet holes allow the proper amount of air to 
mix with the gas. This provides a clean burning flame. Keep 
these holes clear of dust, dirt, lint, and pet hair. Clean these 
air inlet holes prior to each heating season. Blocked air holes 
will create soot. We recommend that you clean the unit every 
three months during operation and have heater inspected yearly by a qualified service person.
We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts 
we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store, or home center may 
carry compressed air in a can. You can use a vacuum cleaner 
in the blow position. If using compressed air in a can, please 
follow the directions on the can. If you don’t follow directions 
on the can, you could damage the pilot assembly.
1.   Shut off the unit, including the pilot. Allow the unit to 
cool for at least thirty minutes.
2.   Inspect burner, pilot, and primary air inlet holes on injec-
tor holder for dust and dirt (see Figure 24).
3.   Blow air through the ports/slots and holes in the burner.
4.   Check the injector holder located at the end of the burner 
tube again. Remove any large particles of dust, dirt, lint, 
or pet hairs with a soft cloth or vacuum cleaner nozzle.
5.   Blow  air  into  the  primary  air  holes  on  the  injector 
holder.
6.   In case any large clumps of dust have now been pushed 
into the burner repeat steps 3 and 4.
Clean the pilot assembly also. A yellow tip on the pilot flame 
indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame 
comes out of the pilot assembly (see Figure 25). With the unit off, 
lightly blow air through the air inlet hole. You may blow through a 
drinking straw if compressed air is not available.
CABINET
AIR PASSAGEWAYS
•   Use a vacuum cleaner or pressurized air to clean.
EXTERIOR
•   Use a soft cloth dampened with a mild soap and water mixture. 
Wipe the cabinet to remove dust.
Figure 25 - Pilot Inlet Air Hole
Pilot Air 
Inlet Hole 
Pilot 
Assembly