Part A - DESIGN LOAD SPECIFICATIONS
A.1
Total Heat Loss _______________Btu/h
A.2
Total Heat Gain _______________Btu/h
Part B - EQUIPMENT SELECTION (Air Handler and Cooling)
AIR HANDLER:
Make:  LIFEBREATH
Model: ____________
B.1
Heating Output ________________________ Btu/h 
(110% - 140% of A.1)
B.2
Equipment External Static Pressure ________ ins. W.C.
(from specs)
B.3
Heating Air Flow Rate
________ cfm
B.4
Circulation Fan Speed (Heating)
________ speed
B.5
Return Air Temperature 
________ 
o
F
B.6
Air Handler Temperature Rise
________ 
o
F
[B.1
 
÷
 (1.08 x B.3)]
B.7
Supply Air Temperature
________ 
o
F
(B.5 
+
 B.6)
B.8
Water Supply Rate
________ US GPM
(from specs)
B.9
Water Supply Temperature 
________ 
o
F
B.10 Water Temperature Drop
________ 
o
(min. 20
o
F)
[B.1 
÷
 (500.4 x B.8)]
B.11 Water Return Temperature
________ 
o
(B.9 - B.10)
COOLING EQUIPMENT:
B.12 Cooling Output ________ (Btu/h) ________ tons
(80% - 125% of A.2)
B.13  Manufacturers Flow Rate/Ton
________ (cfm/ton)
B.14 Cooling Air Flow Rate
________ cfm
B.15 Circulation Fan Speed (Cooling)
_______ speed
Part C - EQUIPMENT SELECTION (Water Heater)
DOMESTIC HOT WATER REQUIREMENTS:
C.1
Minimum Storage Capacity 
________ USG
(from page 38, Method A)
                          
or
C.2
Minimum First Hour Rating
________ USG
(from page 38, Method B)
SPACE HEATING REQUIREMENTS:
C.3
Minimum Effective Water 
Heater Output
________ Btu/h
(B.1 x 1.2)
SELECTED WATER HEATER:
Make: ________   
Model: ________
C.4
Storage Capacity
________ USG
Note: Complete C.5 and C.6 only if C.2 was completed. 
C.5
Recovery
________ USG
C.6
First Hour Rating
________ USG
(.85 x (C.4 
+
 C.5))
      
(min. C.2)
C.7
Energy Factor (ef)
________
C.8
Burner Input
________ Btu/h
C.9
Recovery Efficiency
________ %
C.10 Effective Water Heater Output
________ Btu/h
(C.8 x C.9 
÷
 100) 
                 
(min. C.3)