Output Voltage Requirements
26
315889-002
2.11
Shut-Down Response - REQUIRED
Once the VRM/EVRD is operating after power-up, if either the Output Enable signal is 
de-asserted or a specific VID off code is received, the VRM/EVRD must turn off its 
output (the output should go to high impedance) within 500 ms and latch off until 
power is cycled. If the extended VR 10 VID table is selected, the VRM/EVRD should turn 
off its output if VID [6:0] = XX11111. If the VR 11.0 VID table is selected, there are 
four VID off states; VID [6:0] = 0000000, 0000001, 1111110, or 1111111.
§