American Water Heater ATO-505-P Benutzerhandbuch

Seite von 36
Drawing Number:
Drawing Date:
Pres
s
u
re R
e
lief
 Valv
e
3/
4"
 Ball 
Valv
e
3/
4"
 U
n
ion
C
h
ec
k Valv
e
Ke
y
S
Pres
s
ure R
egulat
or
C
irc
ulat
ing Pum
p
Solenoid Valv
e
Boiler D
rain Valv
e
WH-3-D
Domestic Hot W
ater - O
p
ti
o
n
al
 F
reeze Protection
3 Outdoor Tankless W
ater Heaters
Preferred Piping Inst
allation
February 27, 2008
This is not an engineering drawing; it is intended only as a guide and not 
as a replacement for professional engineering project drawings.  
This 
drawing is not intended to describe a complete system.  It is up to the 
contractor or engineer to determine the necessary components and 
configuration of the particular system to be installed.  
The drawing does 
not imply compliance with local building code requirements.  It is the 
responsibility of the engineer or contractor to ensure that the installation is 
in accordance with all local building codes.  Confer with local building 
of
ficials before installation.
Ho
t
W
a
te
r
S
upp
ly
Li
n
e
S
S
Su
b
2
Su
b
1
Pr
im
ar
y
V
acuum
Br
eaker
NO
TE:
outside building struc
tur
e
.   
T
hese ar
e indicat
ed 
b
y
 being abo
v
e
 the dashed line
.
line should be located inside the building 
struc
tur
e
T
he vacuum br
eaker line should be locat
ed inside 
the building struc
tur
e
.
NO
TE:
enclosur
e or r
e
cess bo
x and packed with insulation 
for additional pr
ot
ec
tion.
Out
door
Tankless
W
a
ter Heater
Out
door
Tankless
W
a
ter Heater
C
old 
W
a
ter Supply Line 
G
as Supply Line 
Out
door
Tankless
W
a
ter Heater
IMPOR
TANT!
W
ith elec
trical po
w
er supplied t
o
 a 
Tankles 
wat
er heat
er
, it will not 
fr
eez
e
 in en
viornments as cold as 
-30ºF
, when pr
ot
ec
ted fr
om dir
ec
wind exposur
e
.
In
 the ev
ent of a po
w
er failur
e at 
temperatur
es belo
w
 fr
eezing
, the 
wat
er heater should be drained of 
all water t
o
 pr
ev
ent fr
eezing 
damage
.
T
he unit ma
y be drained manually 
or thr
ough the installation of the 
Optional solenoid valv
es as sho
wn.
T
he elec
trical c
onnec
tions f
or the 
tw
o solenoid valv
es should be tied 
to
 the 120 
V po
w
er t
erminals 
pr
o
vided on the PC Boar
d of the 
water heat
er
.
When the elec
trical po
w
er t
o
 the 
wat
er heater fails
, the c
old water 
supply solenoid valv
e closes
heat
er
, and the drain do
wn 
solenoid valv
e opens
, allo
wing the 
wat
er heater and associated piping 
to
 drain.  Ensur
e that y
ou run the 
drain f
or the solenoids per local 
codes
.
Route drain
per local c
odes
17
Tankless
Equipment List 
QTY
Tankless Outdoor            3
W
a
ter Heaters
Electronic Connection *
* Refer to Tankless Accessories 
  and Model 
Applicability for
  electronic connection details.
Normally Closed S
olenoid 
V
alv
e
(F
ull Siz
e
 of C
old 
W
a
ter Supply Line)
1/4 “ 
M
inimum
Normally Open 
Solenoid V
alv
e