the  water  heater  must  be  placed  on  a  metal  or  wood  panel 
extending beyond the full width and depth by at least 3 inches 
in any direction. If the heater is installed in a carpeted alcove, 
the  entire  floor  shall  be  covered  by  the  panel.  Also,  see  the 
DrAInInG requirements in MAInTenAnCe Section.
THe HeATer SHAll be lOCATeD Or PrOTeCTeD SO IT 
IS  nOT  SUbJeCT  TO  PHYSICAl  DAMAGe  bY  A  MOVInG 
VeHICle.
FlAMMAble ITeMS, PreSSUrIZeD COnTAInerS Or AnY 
OTHer  POTenTIAl  FIre  HAZArDOUS  ArTICleS  MUST 
neVer  be  PlACeD  On  Or  ADJACenT  TO  THe  HeATer.  
OPen  COnTAInerS  Or  FlAMMAble  MATerIAl  SHOUlD 
nOT be STOreD Or USeD In THe SAMe rOOM WITH THe 
HeATer.
THe HeATer MUST nOT be lOCATeD In An AreA WHere 
IT WIll be SUbJeCT TO FreeZInG.
lOCATe IT neAr A FlOOr DrAIn. THe HeATer SHOUlD 
be  lOCATeD  In  An  AreA  WHere  leAKAGe  FrOM 
HeATer Or COnneCTIOnS WIll nOT reSUlT In DAMAGe 
TO  ADJACenT  AreA  Or  TO  lOWer  FlOOrS  OF  THe 
STrUCTUre.
WHen SUCH lOCATIOnS CAnnOT be AVOIDeD, A SUITAble 
DrAIn PAn SHOUlD be InSTAlleD UnDer HeATer. Such 
pans should be fabricated with sides at least 2” deep, with length 
and width at least 2” greater than diameter of heater and must 
be piped to an adequate drain. Pan must not restrict combustion 
air flow.
ClearanCes
This  water  heater  is  approved  for  installation  on  combustible 
flooring in an alcove with minimum clearance from combustion 
construction as indicated in Figure 7 and Table 4.
In  all  installations  the  minimum  combustible  clearances  from 
vent piping shall be 6” (15.2 cm). Vent piping passing through a 
combustible wall or ceiling must be a continuous run (no joints) 
and retain 6” (15.2 cm) clearance unless an approved reducing 
thimble is used.
A service clearance of at least 24” (61 cm) should be maintained 
from serviceable parts.
The units are approved for installation with side, rear and ceiling 
clearances as indicated below:
taBle 4. minimum ClearanCes to ComBustiBle or 
non-ComBustiBle ContruCtion
Model
"A" right Side "b" left Side "C" back "D" Ceiling
bCl3 95T199 
6nOX
0"
0"
0"
12"
0 cm
0 cm
0 cm
30.5 cm
(A)bCl3 
85T275 6nOX
0"
0"
0"
12"
0 cm
0 cm
0 cm
30.5 cm
(A)bCl3 
85T390 6nOX
0"
0"
0"
12"
0 cm
0 cm
0 cm
30.5 cm
loCating the water heater
Property Damage Hazard
All water heaters eventually leak.
Do not install without adequate drainage.
CAUTION
When  installing  the  heater,  consideration  must  be  given  to 
proper  location.    location  selected  should  be  as  close  to  the 
stack or chimney as practicable, with adequate air supply and as 
centralized with the piping system as possible.
Fire or Explosion Hazard
Read instruction manual before
installing, using or servicing
water heater.
Avoid all ignition sources if you smell gas.
Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
Use only the gas shown on the water heater rating label.
Keep ignition sources away from faucets after extended
periods of non-use.
Maintain required clearances to combustibles.
Do not expose water heater controls to excessive gas
pressure.
THere  IS A  rISK  In  USInG  FUel  bUrnInG APPlIAnCeS 
SUCH AS GAS WATer HeATerS In rOOMS, GArAGeS Or 
OTHer  AreAS  WHere  GASOlIne,  OTHer  FlAMMAble 
lIqUIDS  Or  enGIne  DrIVen  eqUIPMenT  Or  VeHICleS 
Are  STOreD,  OPerATeD  Or  rePAIreD.  FlAMMAble 
VAPOrS  Are  HeAVY  AnD  TrAVel  AlOnG  THe  FlOOr 
AnD MAY be IGnITeD bY THe HeATer’S IGnITer Or MAIn 
bUrner  FlAMeS  CAUSInG  FIre  Or  eXPlOSIOn.  SOMe 
lOCAl CODeS PerMIT OPerATIOn OF GAS APPlIAnCeS 
In  SUCH  AreAS  IF  THeY  Are  InSTAlleD  18”  Or  MOre 
AbOVe  THe  FlOOr.  THIS  MAY  reDUCe  THe  rISK  IF 
lOCATIOn In SUCH An AreA CAnnOT be AVOIDeD.
DO  nOT  InSTAll  THIS  WATer  HeATer  DIreCTlY  On  A 
CArPeTeD FlOOr.  A FIre HAZArD MAY reSUlT. Instead