American Water Heater BCG3 Benutzerhandbuch

Seite von 52
12
addition  adjustment    maybe  required  later  to  maintain  a 
steady gas supply pressure.
4.  When  installing  multiple  water  heaters  in  the  same  gas 
supply  system  it  is  recommended  that  individual  positive 
lock-up gas pressure regulators be installed at each unit.
power supply
The water heaters covered in this manual require a 120 VAC, 
1Ø (single phase), 60hz, 15 amp power supply and must also 
be electrically grounded in accordance with local codes or, in the 
absence of local codes, with the national electrical Code, AnSI/
nFPA 70 or the Canadian electrical Code, CSA C22.1.
water temperature Control and mixing ValVes
Water temperature over 125°F (52°C)
can cause severe burns instantly
resulting in severe injury or death.
Children, the elderly and the
physically or mentally disabled are at
highest risk for scald injury.
Feel water before bathing or
showering.
Temperature limiting devices such as
mixing valves must be installed
when required by codes and to
ensure safe temperatures at fixtures.
Water heated to a temperature which will satisfy clothes washing, 
dish washing, and other sanitizing needs can scald and cause 
permanent injury upon contact. Short repeated heating cycles 
caused by small hot water uses can cause temperatures at the 
point of use to exceed the water heater’s temperature setting by 
up to 20°F (11°C).
Some  people  are  more  likely  to  be  permanently  injured  by 
hot water than others. These include the elderly, children, the 
infirm and the physically/mentally disabled. Table 6 shows the 
approximate  time-to-burn  relationship  for  normal  adult  skin. 
If anyone using hot water provided by the water heater being 
installed fits into one of these groups or if there is a local code 
or state law requiring a certain water temperature at the point of 
use, then special precautions must be taken.
In addition to using the lowest possible temperature setting that 
satisfies the demand of the application a Mixing Valve should be 
installed at the water heater (see Figure 10) or at the hot water 
taps to further reduce system water temperature.
Mixing valves are available at plumbing supply stores. Consult 
a  Qualified  Installer  or  Service  Agency.  Follow  mixing  valve 
manufacturer’s instructions for installation of the valves.
taBle 6.
Water Temperature 
°F (°C)
Time for 1st Degree Burn 
(less Severe Burns)
Time for Permanent Burns 
2nd & 3rd Degree 
(Most Severe Burns)
110 (43)
(normal shower temp.)
116 (47)
(pain threshold)
116 (47)
35 minutes
45 minutes
122 (50)
1 minute
5 minutes
131 (55)
5 seconds
25 seconds
140 (60)
2 seconds
5 seconds
149 (65)
1 second
2 seconds
154 (68)
instantaneous
1 second
(U.S. Government Memorandum, C.P.S.C., Peter l. Armstrong, Sept. 15, 1978)
gas supply system
low pressure building gas supply systems are defined as those 
systems  that  cannot  under  any  circumstances  exceed  14” 
W.C. (1/2 PSI Gauge). These systems do not require pressure 
regulation.  Measurements  should  be  taken  to  insure  that  gas 
pressures are stable and fall within the requirements stated on the 
water heater rating plate. readings should be taken with all gas 
burning equipment off (static pressure) and with all gas burning 
equipment running at maximum rate (dynamic pressure). The gas 
supply pressure must be stable within 1.5” W.C. from static to 
dynamic pressure to provide good performance. Pressure drops 
that exceed 1.5” W.C. may cause rough starting, noisy combustion 
or nuisance outages. Increases or spikes in static pressure during 
off cycles may cause failure to ignite or in severe cases damage to 
appliance gas valves. If your low pressure system does nOT meet 
these requirements, the installer is responsible for the corrections.
high Pressure building supply systems use pressures that exceed 
14” W.C. (1/2 PSI Gauge). These systems must use field supplied 
regulators to lower the gas pressure to less than 14” W.C. (1/2 PSI 
Gauge). Appliances require gas regulators that are properly sized 
for the water heater input and deliver the rating plate specified 
pressures. Gas supply systems where pressure exceeds 5 PSI 
often require multiple regulators to achieve desired pressures. 
Systems in excess of 5 PSI building pressure should be designed 
by gas delivery professionals for best performance. Water heaters 
connected to gas supply systems that exceed 14” W.C. (1/2 PSI 
Gauge) at any time must be equipped with a gas supply regulator.
gas pressure reQuirements
All models require a minimum gas supply pressure of 5.2” W.C. 
The minimum supply pressure is measured while gas is flowing 
(dynamic pressure). The supply pressure (dynamic) should never 
fall below 5.2” W.C. The supply pressure should be measured 
with  all  gas  fired  appliances  connected  to  the  common  main 
firing at full capacity. If the supply pressure drops more than 1.5” 
W.C. as gas begins to flow to the water heater then the supply 
gas system including the gas line and/or the gas regulator may 
be restricted or undersized. See Supply Gas regulator section 
and Gas Piping section of this manual. The low gas pressure 
switch will shut down the water heater if the supply gas pressure 
drops below the minimum allowable value.
The gas valve on all models has a maximum gas supply pressure 
limit  of  14"  W.C.  The  maximum  supply  pressure  is  measured 
while gas is not flowing (static pressure).
supply gas regulator
The  maximum  allowable  gas  supply  pressure  for  this  water 
heater is 14.0 inches W.C. (3.48 kPa). Install a positive lock-up 
gas pressure regulator in the gas supply line if inlet gas pressure 
can exceed 14.0 inches W.C. (3.48 kPa) at any time.
If a positive lock-up regulator is required follow these instructions:
1.  Positive lock-up gas pressure regulators must be rated at or 
above the input Btu/hr rating of the water heater they supply.
2.  Positive lock-up gas pressure regulator(s) should be installed no 
closer than 3 feet (1 meter) and no farther than 8 feet (2.4 meters) 
of equivalent length from the water heater’s inlet gas connection.
3.  After installing the positive lock-up gas pressure regulator(s) 
an  initial  nominal  supply  pressure  setting  of  7.0”  W.C. 
while  the  water  heater  is  operating  is  recommended  and 
will  generally  provide  good  water  heater  operation.  Some 
installation reQuirements