American Water Heater BCG3 Benutzerhandbuch

Seite von 52
32
TABle 11:
1 FlASh
System lockout (retries or cycles exceeded)
2 FlASheS Pressure switch stuck close
3 FlASheS Pressure switch stuck open
4 FlASheS Open on high temperature limit switch (eco)
6 FlASheS 115 volt AC power reversed (check polarity)
7 FlASheS low flame sense signal (make sure flame sensor 
is in burner flame)
8 FlASheS Check igniter
continuous  flash  ->  continuous  flame  sensed  >  5  seconds 
without gas valve
continuous on -> internal control failure - replace ignition control 
module.
Use this diagnostic system in conjunction with “OPerATIOnAl 
CheCKlIST”  and  the  “SeQUenCe  OF  OPerATIOn”  to 
troubleshoot the appliance.
eleCtriCal serViCing
lABel All  WIreS  PrIOr  TO  DISCOnneCTIOn  When 
SerVICInG    COnTrOlS.  WIrInG  errOrS  CAn  CAUSe 
IMPrOPer AnD DAnGerOUS OPerATIOn.
VerIFY PrOPer OPerATIOn AFTer  SerVICInG.
The installer may be able to observe and correct certain problems 
which may arise when the unit is put into operation.  hOWeVer, 
it  is  recommended  that  only  qualified  service  agents,  using 
appropriate test equipment, be allowed to service the heater.
As  preliminary  step,  check  wiring  against  diagram,  check  for 
grounded, broken or loose wires.  Check all wire ends to be sure 
that they are making good contact.
ignition module system
Before calling your service agent, the following checklist should 
be examined to eliminate obvious problems from those requiring 
replacement or servicing.
•  Check that “main manual gas shutoff valve” is fully open and 
that gas service has not been interrupted.
•  Check  that  after  following  the  appliance  OPerATInG 
InSTrUCTIOnS, the “Top Knob” of the appliance gas valve 
is in “On” position.
•  Check electrical supply to the appliance for possible blown 
(or  tripped)  fusing  or  power  interruption.  Also  check  the  3 
amp fuse on the front of the digital thermostat (Fig. 2).
•  Is the water temperature in tank below the thermostat dial 
setting on the appliance thermostat (calling for heat)?
•  It  is  possible  that  the  high  limit  (e.C.O.)  has  functioned  to 
shut off the appliance. See high limit page 7 - high limit 
Switch  for  reset  procedure.  Contact  your  service  agent  if 
limit continues to function to shut off appliance. 
system diagnostiCs
Your  water  heater  is  equipped  with  an  ignition  module  that 
incorporates a diagnostic system to assist in troubleshooting the 
appliance. The indicator codes on the ignition module are as follows:
serViCe