The heATer MUST nOT Be lOCATeD In An AreA Where IT 
WIll Be SUBJeCT TO FreeZInG.
lOCATe IT neAr A FlOOr DrAIn. The heATer ShOUlD Be 
lOCATeD In An AreA Where leAKAGe FrOM heATer Or 
COnneCTIOnS WIll nOT reSUlT In DAMAGe TO ADJACenT 
AreA Or TO lOWer FlOOrS OF The STrUCTUre.
When SUCh lOCATIOnS CAnnOT Be AVOIDeD, A SUITABle 
DrAIn PAn ShOUlD Be InSTAlleD UnDer heATer. Such 
pans  should  be  fabricated  with  sides  at  least  2”  deep,  with 
length  and  width  at  least  2”  greater  than  diameter  of  heater 
and must be piped to an adequate drain. Pan must not restrict 
combustion air flow.
ClearanCes
This water heater is approved for installation on combustible flooring 
(with  nSF  leg  kit  #9003425205)  in  an  alcove  when  minimum 
clearance  from  any  combustion  construction  are  followed  as 
indicated in Figure 6 and Table 4.
In all installations the minimum combustible clearances from vent piping 
shall be 6” (152 mm). Vent piping passing through a combustible wall  
or ceiling must be a continuous run (no joints) and retain 6” (152 
mm) clearance unless an approved reducing thimble is used.
A service clearance of at least 24” (61 cm) should be maintained 
from serviceable parts.
The units are approved for installation with side, rear and ceiling 
clearances as indicated below:
taBle 4.
minimum ClearanCes to ComBustiBles in inChes (mm)
model
“a” right side “B” left side
“C” BaCk
“d” Ceiling
BCG3 70T120 5nOX
2” 51 mm
2” 51 mm
2” 51 mm
12” 305 mm
BCG3 80T150 6nOX
2” 51 mm
2” 51 mm
2” 51 mm
12” 305 mm
BCG3 100T180 6nOX
2” 51 mm
2” 51 mm
2” 51 mm
12” 305 mm
BCG3 95T199 6nOX
2” 51 mm
2” 51 mm
2” 51 mm
12” 305 mm
BCG3 100T199 6nOX
2” 51 mm
2” 51 mm
2” 51 mm
12” 305 mm
A/BCG3 100T200 6nOX
2” 51 mm
2” 51 mm
2” 51 mm
12” 305 mm
A/BCG3 100T250 6nOX
2” 51 mm
2” 51 mm
2” 51 mm
12” 305 mm
A/BCG3 100T275 6nOX
2” 51 mm
2” 51 mm
2” 51 mm
12” 305 mm
A/BCG3 85T310 6nOX
6” 152 mm
6” 152 mm
6” 152 mm
12” 305 mm
A/BCG3 85T366 6nOX
6” 152 mm
6” 152 mm
6” 152 mm
12” 305 mm
A/BCG3 85T390 6nOX
3” 76 mm
3” 76 mm
3” 76 mm
12” 305 mm
taBle 5.
minimum ClearanCes to non-ComBustiBle ConstruCtion
model
“a” right side “B” left side
“C” BaCk
“d” Ceiling
BCG3 70T120 5nOX
0” 0 mm
0” 0 mm
0” 0 mm
12” 305 mm
BCG3 80T150 6nOX
0” 0 mm
0” 0 mm
0” 0 mm
12” 305 mm
BCG3 100T180 6nOX
0” 0 mm
0” 0 mm
0” 0 mm
12” 305 mm
BCG3 95T199 6nOX
2” 51 mm
2” 51 mm
2” 51 mm
12” 305 mm
BCG3 100T199 6nOX
0” 0 mm
0” 0 mm
0” 0 mm
12” 305 mm
A/BCG3 100T200 6nOX
0” 0 mm
0” 0 mm
0” 0 mm
12” 305 mm
A/BCG3 100T250 6nOX
0” 0 mm
0” 0 mm
0” 0 mm
12” 305 mm
A/BCG3 100T275 6nOX
0” 0 mm
0” 0 mm
0” 0 mm
12” 305 mm
A/BCG3 85T310 6nOX
3” 76 mm
3” 76 mm
3” 76 mm
12” 305 mm
A/BCG3 85T366 6nOX
0” 0 mm
0” 0 mm
0” 0 mm
12” 305 mm
A/BCG3 85T390 6nOX
0” 0 mm
0” 0 mm
0” 0 mm
12” 305 mm
loCating the water heater
Property Damage Hazard
All water heaters eventually leak.
Do not install without adequate drainage.
CAUTION
When installing the heater, consideration must be given to proper 
location.  location selected should be as close to the stack or chimney 
as practicable, with adequate air supply and as centralized with the 
piping system as possible.
Fire or Explosion Hazard
Read instruction manual before
installing, using or servicing
water heater.
Avoid all ignition sources if you smell gas.
Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
Use only the gas shown on the water heater rating label.
Keep ignition sources away from faucets after extended
periods of non-use.
Maintain required clearances to combustibles.
Do not expose water heater controls to excessive gas
pressure.
There IS A rISK In USInG FUel BUrnInG APPlIAnCeS SUCh 
AS GAS WATer heATerS In rOOMS, GArAGeS Or OTher 
AreAS Where GASOlIne, OTher FlAMMABle lIQUIDS Or 
enGIne DrIVen eQUIPMenT Or VehICleS Are STOreD, 
OPerATeD Or rePAIreD. FlAMMABle VAPOrS Are heAVY 
AnD TrAVel AlOnG The FlOOr AnD MAY Be IGnITeD BY The 
heATer’S IGnITer Or MAIn BUrner FlAMeS CAUSInG FIre 
Or eXPlOSIOn. SOMe lOCAl CODeS PerMIT OPerATIOn OF 
GAS APPlIAnCeS In SUCh AreAS IF TheY Are InSTAlleD 18” 
Or MOre ABOVe The FlOOr. ThIS MAY reDUCe The rISK IF 
lOCATIOn In SUCh An AreA CAnnOT Be AVOIDeD.
DO  nOT  InSTAll  ThIS  WATer  heATer  DIreCTlY  On A 
CArPeTeD FlOOr.  A FIre hAZArD MAY reSUlT. Instead the 
water heater must be placed on a metal or wood panel extending 
beyond the full width and depth by at least 3 inches in any direction. 
If the heater is installed in a carpeted alcove, the entire floor shall 
be covered by the panel. Also, see the DrAInInG requirements in 
MAInTenAnCe Section.
The heATer ShAll Be lOCATeD Or PrOTeCTeD SO IT IS nOT 
SUBJeCT TO PhYSICAl DAMAGe BY A MOVInG VehICle.
FlAMMABle ITeMS, PreSSUrIZeD COnTAInerS Or AnY OTher 
POTenTIAl FIre hAZArDOUS ArTICleS MUST neVer Be PlACeD 
On Or ADJACenT TO The heATer.  OPen COnTAInerS Or 
FlAMMABle MATerIAl ShOUlD nOT Be STOreD Or USeD 
In The SAMe rOOM WITh The heATer.
installation Considerations