American Water Heater RESIDENTIAL HYBRID ELECTRIC HEAT PUMP WATER HEATER Benutzerhandbuch

Seite von 48
15
FUS202
FUS201
CN207
CN201
Figure 6
CN202
CN206
Section “A”
CN 201 Line Power:
•  Pin 1 - Control board power wire L1 (240VAC)
•  Pin 2 - Control board power wire L2 (240VAC)
•  Pin 3 - Not used
•  Pin 4 - Control board power wire ground
CN 202 ECO Bottom:
•  Pin 1 - Connect to lower heating element
•  Pin 2 - Connect to L1 behind ECO switch 
CN 206 Compressor:
  
•  Pin 1 - Compressor power L1
•  Pin 2 - Unused
•  Pin 3 - Unused
•  Pin 4 - Compressor power L2 
CN 207 Fan Low/high:
•  Pin 1 - Fan power L1
•  Pin 2 - Unused
•  Pin 3 - Fan power
FUS 201:
•  Fuse 201 (3 Amp, 250V, slow blow) fuses the L1 power leg coming to the Control Board
FUS 202:
•  Fuse 202 (3 Amp, 250V, slow blow) fuses the L2 power leg coming to the Control Board
Section “A” of Control Board