American Water Heater HPE10260H045DV Benutzerhandbuch

Seite von 48
29
Powered Anode Check Flow Chart
Powered anode 
Fault
Check 
connection at 
anode
Check 
voltage ≈ 
2.5 Vdc
Check 
connection at 
ground
Check 
connection on 
control board @ 
CN203
Disconnect 
CN203 
and measure 
resistance between 
pin1 and tab at 
end of wire 
≈100Ω
Bad
Good
Bad
Good
Bad
Good
Reconnect 
terminal to 
powered 
anode
Reconnect 
terminal to 
control board 
@ CN203
Reconnect 
ground to 
terminal in 
bottom of control 
board box
Disconnect wire 
from powered 
anode
Fault 
cleared?
Yes
Done
No
Bad
Good
Check 
resistance 
from anode center 
tab to tank 
≥1MΩ
Bad
Remove 
anode and 
check resistance 
from threaded portion 
of anode to the 
tab ≥1MΩ
Bad Replace 
anode
Good
Check 
that upper 
element is 
folded
No
Replace 
element 
with folded 
type
Yes
Clean threads on 
powered anode and 
tank threads, apply 
tefl on® tape to anode, 
re-install and re-connect
Restore 
power
Fault 
cleared?
Yes
No
Call tech 
services
Good
Replace 
control 
board *
Bad
Replace  
anode 
wire
Place unit in 
standby mode 
and turn power 
off at breaker/
fuse panel
Fault 
cleared?
Fault 
cleared?
Yes
Yes
No
No
Call tech services
*If replacing the control board does not resolve the issue, contact technical support.