WATER CONNECTIONS
 
 
Note:  BEFORE PROCEEDING WITH THE INSTALLATION, CLOSE THE 
MAIN WATER SUPPLY VALVE. 
After shutting off the main water supply, open a faucet to relieve the water 
line pressure to prevent any water from leaking out of the pipes while making 
the water connections to the water heater.  After the pressure has been 
relieved, close the faucet.  The COLD water inlet and HOT water outlet are 
identified on the top of the water heater.  The fittings at the cold water inlet 
and hot water outlet are dielectric waterway fittings with 3/4” NPT male 
thread.  Make the proper plumbing connections between the water heater 
and the plumbing system to the house.  Install a shut-off valve in the cold 
water supply line. 
 
 
      
CAUTION
 
If sweat fittings are to be used, DO NOT apply heat to the nipples on top 
of the water heater.  Sweat the tubing to the adapter before fitting the 
adapter to the water connections.  It is imperative that heat is not applied 
to the nipples containing a plastic liner.