Servicing should only be performed by a Qualified Service Agent
23
OPERATION & SERVICE
Heating Element Amperage Test
This test should be considered as a first diagnostic procedure for the common service 
complaints of no hot water or not enough hot water. The heating element amperage test 
shown on this page is the best procedure to quickly determine which (if any) heating 
elements are not working properly.
1
Secure power to the water heater at the main breaker or disconnect switch.
2
Ensure tank temperature is less than 100°F/38°C - dump water to lower tank temperature if necessary.
3
Surface Mount Control Models - raise the temperature settings to ensure a call heat is active for all 
heating elements. Press the red reset button firmly on all thermostat/ECO controls then raise the 
temperature setting on all thermostat/ECO controls to 140°F or higher - see page 18.
4
Restore power to the water heater.
5
Electronic Control Models - adjust the temperature settings to ensure a call heat is active for all heating 
elements. Raise the Operating Set Point in the Temperatures Menu to 140°F or higher. Set all Heating 
Element Bank Differentials in the Temperatures Menu to 2°F - see pages 52 and 53.
6
Using a clamp style AC amp meter: set the amp meter to an AC amperage range just above the expected 
amperage (100 AC amp range initially). Measure and record the amperage at all heating elements by 
clamping the jaws of the meter around ONLY one of the wires to each heating element. See the image 
below. Heating element amp readings should be approximately the same for all heating elements. The 
normal operating amps for all heating elements is provided in the Heating Element Amperage table on 
page 22 or it can be calculated using ohms law as explained on page 11
Service Note: Check all power circuit wiring to the heating element(s) on any element drawing zero or low 
amps - see the wiring diagram on the water heater. On Electronic Control Models check the contactors on 
any heating element(s) drawing zero or low amps - see pages 29 - 33. Perform the Heating Element 
Voltage and Heating Element Resistance & Ground tests (see pages 24 - 26) on any heating elements 
drawing zero amps or any heating element drawing less than normal operating amps.
If the measured amp draw on any element is considerably less or more than the normal operating amps 
ensure the voltage and KW rating of those heating elements is the correct value for the water heater being 
serviced - see Heating Element Ratings and Heating Element Configurations on page 21.
Measuring amperage on an electric heating element.
Make sure the jaws of the AC amp meter are clamped
around ONLY ONE WIRE to the heating element
being tested. Clamping around more than one wire
often gives a false zero amp reading.
DO NOT TOUCH THE ENDS OF ANY
HEATING ELMENTS WHILE PERFORMING
THIS TEST
Be extremely careful as there will be high voltage
present at the wiring terminals on all heating 
elements during this test.