terMInatIon clearances sIdewall dIrect vent
V
X
VENT TERMINAL
AIR SUPPLY INLET
AREA WHERE TERMINAL IS NOT PERMITTED
v
v
A
G
V
FIXED
CLOSED
FIXED
CLOSED
OPERABLE
OPERABLE
V
C
B
B
B
B
F
B
V
V
A
J
V
H
M
X
X
V
V
K
B
E
D
L
DIRECT VENT
(using outdoor air for combustion)
EXTERIOR CLEARANCES FOR SIDEWALL VENT TERMINATION
fIGure 14
Vent terminal clearances for “Direct Vent” installations. Direct Vent configurations use outdoor air for combustion.
us InstallatIons 1
us InstallatIons 1
a
Clearance above grade, 
veranda, porch, deck or 
balcony
12 inches (30 cm)
h
Clearance to each side 
of center line extended 
above meter/regulator 
assembly
3 feet (91 cm) within a height 
15 feet (4.5 m) above the 
meter/regulator assembly*
b
Clearance to window or 
door that may be opened
6 inches (15 cm) 
for appliances up to 
10,000 Btu/hr (3 kW), 
9 inches (23 cm) for 
appliances between 
10,000 Btu/hr (3 kW) 
and 50,000 Btu/hr (15 
kW), 12 inches (30 cm) 
for appliances above 
50,000 Btu/hr (15 kW)
I
Clearance to service 
regulator vent outlet
3 feet (91 cm)*
c
Clearance to 
permanently closed 
window
6 inches (15 cm)*
j
Clearance to a non 
mechanical air supply 
inlet into building or 
combustion air inlet to 
any other appliance
6 inches (15 cm) for 
appliances up to 10,000 
Btu/hr (3 kW), 9 inches (23 
cm) for appliances between 
10,000 Btu/hr (3 kW) and 
50,000 Btu/hr (15 kW), 12 
inches (30 cm) for appliances 
above 50,000 Btu/hr (15 kW)
d
Vertical clearance to 
ventilated soffit located 
above the terminal within 
a horizontal distance of 
2 feet (61 cm) from the 
center line of the terminal
12 inches (30 cm)*
K
Clearance to a 
mechanical air supply 
inlet
3 feet (91 cm) above if within 
10 feet (3 m) horizontally
e
Clearance to unventilated 
soffit
12 inches (30 cm)*
l
Clearance above 
paved sidewalk or 
paved driveway located 
on public property
7 feet (2.13 m)†*
f
Clearance to outside 
corner
2 feet (60 cm)*
M
Clearance under 
veranda, porch, deck, 
or balcony
12 inches (30 cm) ‡*
G
Clearance to inside 
corner
18 inches (45 cm)*
1 In accordance with the current ANSI Z223.1/NFPA 54, National Fuel Gas Code.
† A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings.
‡ Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.
* Clearance in accordance with local installation codes and the requirements of the gas supplier and the manufacturer’s installation instructions.