Valves for reducing the point-of-use temperature by mixing cold and 
hot water are available. Also available are inexpensive devices that 
attach to faucets to limit hot water temperatures. Contact a licensed 
plumber or the local plumbing authority.
The table below shows the approximate time-to-burn relationship for 
normal adult skin. Short repeated heating cycles caused by small hot water 
uses can cause temperatures at the point of use to exceed the thermostat 
setting by up to 20°F/11°C. If you experience this type of use, you should 
consider using lower temperature settings to reduce scald hazards.
In all cases, the following burn table must be used. It’s appearance 
may be altered to comply with each manual’s style, but the content 
must remain unchanged. NOTE: If the manual is to be used outside 
of the United States, metric equivalents (Celsius) must be added to 
the table.
Table 11
Water Temperature 
°F (°C)
Time for 1st Degree Burn
(Less Severe Burns)
Time for Permanent Burns
2nd & 3rd Degree
(Most Severe Burns)
110 (43.3)
(normal shower temp.)
116 (46.7)
(pain threshold)
116 (46.7)
35 minutes
45 minutes
122 (50)
1 minute
5 minutes
131 (55)
5 seconds
25 seconds
140 (60)
2 seconds
5 seconds
149 (65)
1 second
2 seconds
154 (67.8)
instantaneous
1 second
(U.S. Government Memorandum, C.P.S.C., Peter L. Armstrong, Sept. 15, 1978)
HI LIMIT SWITCH (ECO)
This  water  heater  is  equipped  with  an  ECO  (energy  cut  out)  non 
adjustable  high  temperature  limit  switch.  The  ECO  is  a  normally 
closed switch that opens (activates) on a rise in temperature. The 
ECO is located inside the Temperature Probe (two red wires). The 
ECO switch contacts will open when the water temperature reaches 
approximately 202°F (94°C) and close at approximately 140°F (49°C).
If the ECO activates (contacts open) due to abnormally high water 
temperatures in the storage tank the control system will immediately 
de-energize  the  24  VAC  Gas  Control  Valve  and  end  the  current 
heating  cycle.  The  control  system  will  lock  out  disabling  further 
heating operation. The control system will display the Energy Cut 
Out (ECO) Fault message on the LCD screen. It is important that 
a  Qualified  Service  Technician  be  contacted  to  determine  the 
reason for the ECO activation before resetting the ECO. Once the 
reason has been determined and corrected the ECO can be reset 
as follows:
Should  the  ECO  activate,  the  water  temperature  must  drop  below 
140°F (49°C) before the control system can be reset. Once the water 
temperature has cooled below this point the power supply to the water 
heater must be turned off and on again to reset the control system.
Contact your dealer or servicer if continued high limit switch operation 
occurs.
It is recommended that lower water temperatures be used to avoid 
the risk of scalding. It is further recommended, in all cases, that the 
water temperatures be set for the lowest temperature which satisfies 
your hot water needs. This will also provide the most energy efficient 
operation of the water heater.
HOT WATER CAN SCALD: Water heaters are intended to produce 
hot water. Water heated to a temperature which will satisfy space 
heating, clothes washing, dish washing, and other sanitizing needs 
can scald and permanently injure you upon contact. Some people 
are more likely to be permanently injured by hot water than others. 
These include the elderly, children, the infirm, or physically/mentally 
handicapped. If anyone using hot water from this heater fits into one of 
these groups or if there is a local code or state law requiring a certain 
temperature water at the hot water tap, then you must take special 
precautions. In addition to using the lowest possible temperature 
setting that satisfies your hot water needs, a means such as a mixing 
valve, should be used at the hot water taps used by these people or 
at the water heater. Mixing valves are available at plumbing supply 
or hardware stores. Follow manufacturer’s instructions for installation 
of the valves. Before changing the factory setting on the thermostat, 
read the Temperature Regulation section in this manual.
Never allow small children to use a hot water tap, or to draw their own 
bath water. Never leave a child or handicapped person unattended 
in a bathtub or shower.
SETTING THE WATER HEATER TEMPERATURE AT 120°F/49°C 
WILL REDUCE THE RISK OF SCALDS. Some states require settings 
at specific lower temperatures.
The water temperature is controlled using the Temperature Control on 
the Display at the front of the unit (See “Figure 1B: 50 GALLON UNIT” 
& “Figure 1C: 75 GALLON UNIT”). This control utilizes a temperature 
probe to determine the tank temperature. The temperature probe is 
located behind the heater’s front display.
The temperature may be adjusted from 90°F/32°C to 160°F/71°C. The 
temperature was preset to 120°F/49°C before the heater was shipped 
from the factory. It is recommended that lower water temperature be 
used to avoid the risk of scalding. It is further recommended, in all 
cases, that the water temperature be set for the lowest temperature 
which satisfies your hot water needs. This will also provide the most 
energy efficient operation of the water heater and minimize scale 
formation.