PRECAUTIONS
DO NOT USE THIS WATER HEATER IF ANY PART HAS BEEN 
UNDER  WATER.  Immediately  call  a  qualified  service  agency  to 
inspect the water heater and to make a determination on what steps 
should be taken next.
If the unit is exposed to the following, do not operate heater until all 
corrective steps have been made by a qualified service agency.
1.  External fire.
2.  Damage.
3.  Firing without water.
GROUNDING INSTRUCTIONS
This water heater must be grounded in accordance with the National 
Electrical Code and/or local codes. These must be followed in all 
cases. Failure to ground this water heater properly may also cause 
erratic control system operation.
This  water  heater  must  be  connected  to  a  grounded  permanent 
wiring  system;  or  an  equipment  grounding  conductor  must  be 
run  with  the  circuit  conductors  and  connected  to  the  equipment 
grounding terminal or lead on the water heater.
HYDROGEN GAS FLAMMABLE
Explosion Hazard
Flammable hydrogen gases
may be present.
Keep all ignition sources away
from faucet when turning on
hot water.
Hydrogen  gas  can  be  produced  in  a  hot  water  system  served  by 
this  water  heater  that  has  not  been  used  for  a  long  period  of 
time  (generally  two  weeks  or  more).  Hydrogen  gas  is  extremely 
flammable. To reduce the risk of injury under these conditions, it is 
recommended that a hot water faucet served by this water heater 
be opened for several minutes before using any electrical appliance 
connected to the hot water system. If hydrogen is present there will 
probably be an unusual sound such as air escaping through the pipe 
as  the  water  begins  to  flow. THERE SHOULD BE NO SMOKING 
OR OPEN FLAME NEAR THE FAUCET AT THE TIME IT IS OPEN. 
Read and understand this instruction
manual and the safety messages
herein before installing, operating or
servicing this water heater.
Failure to follow these instructions and
safety messages could result in death
or serious injury.
This manual must remain with the
water heater.
Water temperature over 125°F (52°C)
can cause severe burns instantly
resulting in severe injury or death.
Children, the elderly and the
physically or mentally disabled are at
highest risk for scald injury.
Feel water before bathing or
showering.
Temperature limiting devices such as
mixing valves must be installed
when required by codes and to
ensure safe temperatures at fixtures.
Explosion Hazard
Overheated water can cause
water tank explosion.
Properly sized temperature and
pressure relief valve must be
installed in the opening provided.
Verify the power to the water heater is turned off before performing any service procedures.
Improper installation, use and service may result
in property damage.
Do not operate water heater if flood damaged.
Inspect anode rods regularly, replace if damaged.
Install in location with drainage.
Fill tank with water before operation.
Properly sized thermal expansion tanks are required on all
closed water systems.
Refer to this manual for installation and service.
CAUTION
GENERAL SAFETY INFORMATION