American Water Heater VG6250T 110 Benutzerhandbuch

Seite von 60
47
START UP CONDITIONS
SMOKE/ODOR
It is not uncommon to experience a small amount of smoke and odor 
during the initial start-up. This is due to burning off of oil from metal 
parts, and will disappear in a short while.
THERMAL EXPANSION
Water  supply  systems  may,  because  of  such  events  as  high 
line  pressure,  frequent  cut-offs,  the  effects  of  water  hammer 
among  others,  have  installed  devices  such  as  pressure 
reducing  valves,  check  valves,  back  flow  preventers,  etc. 
to  control  these  types  of  problems.  When  these  devices 
are  not  equipped  with  an  internal  by  pass,  and  no  other 
measures  are  taken,  the  devices  cause  the  water  system 
to be closed. As water is heated, it expands (thermal expansion) 
and  closed  systems  do  not  allow  for  the  expansion  of 
heated water.
The  water  within  the  water  tank  expands  as  it  is  heated 
and  increases  the  pressure  of  the  water  system.  If  the 
relieving  point  of  the  water  heater’s  temperature-pressure 
relief valve is reached, the valve will release excess pressure. The 
temperature-pressure relief valve is not intended for the constant 
relief of thermal expansion. This is an unacceptable condition and 
must  be  corrected.  It  is  recommended  that  any  devices 
installed  which  could  create  a  closed  system  have  a 
by-pass  and/or  the  system  have  an  expansion  tank 
or  device  to  relieve  the  pressure  built  by  thermal 
expansion  in  the  water  system.  Expansion  tanks  are 
a v a i l a b l e   f o r   o r d e r i n g   t h r o u g h   a   l o c a l   p l u m b i n g 
contractor.  Contact  the  local  water  heater  supplier 
or  qualified  service  agency  for  assistance  in  controlling  these 
situations.
OPERATIONAL CONDITIONS
SMELLY WATER
In each water heater there is installed at least one anode rod (see 
for  corrosion  protection  of  the  tank.  Certain  water  conditions  will 
cause a reaction between this rod and the water. The most common 
complaint associated with the anode rod is one of a rotten egg smell 
in the hot water. The smell is a result of four factors which must all 
be present for the odor to develop:
a.  A concentration of sulfate in the supply water.
b.  Little or no dissolved oxygen in the water.
c.  A sulfate reducing bacteria which has accumulated within the 
water heater (this harmless bacteria is nontoxic to humans).
d.  An excess of active hydrogen in the tank. This is caused by the 
corrosion protective action of the anode rod.
Smelly water may be eliminated or reduced in some water heater 
models by replacing the anode rod(s) with one of less active material, 
and then chlorinating the water heater tank and all water lines. Contact 
the local water heater supplier or a qualified service agency for further 
information  concerning  an Anode  Rod  Replacement  Kit  and  this 
chlorination treatment.
If  the  smelly  water  persists  after  the  anode  rod  replacement  and 
chlorination treatment, we can only suggest that chlorination or aeration 
of the water supply be considered to eliminate the water problem.
Do not remove the anode rod leaving the tank unprotected. By 
doing so, all warranty on the water heater tank is voided.
AIR IN HOT WATER FAUCETS
HYDROGEN GAS: Hydrogen gas can be produced in a hot water 
system that has not been used for a long period of time (generally 
two  weeks  or  more).  Hydrogen  gas  is  extremely  flammable  and 
explosive. To prevent the possibility of injury under these conditions, 
we  recommend  the  hot  water  faucet,  located  farthest  away,  be 
opened  for  several  minutes  before  any  electrical  appliances 
which are connected to the hot water system are used (such as a 
dishwasher or washing machine). If hydrogen gas is present, there 
will probably be an unusual sound similar to air escaping through the 
pipe as the hot water faucet is opened. There must be no smoking 
or open flame near the faucet at the time it is open.
FOR YOUR INFORMATION