American Water Heater vG6250t76nv Benutzerhandbuch

Seite von 40
30
for Your InforMatIon
start up condItIons
sMoKe/odor
It is not uncommon to experience a small amount of smoke and odor 
during the initial start-up. This is due to burning off of oil from metal 
parts, and will disappear in a short while.
stranGe sounds
Possible noises due to expansion and contraction of some metal parts 
during periods of heat-up and cool-down do not necessarily represent 
harmful or dangerous conditions.
Condensation  causes  sizzling  and  popping  within  the  burner  area 
during heating and cooling periods and should be considered normal. 
See “Condensate” in this manual.
operatIonal condItIons
sMellY water
In  each  water  heater  there  is  installed  at  least  one  anode  rod  for 
corrosion protection of the tank. Certain water conditions will cause a 
reaction between this rod and the water. The most common complaint 
associated with the anode rod is one of a “rotten egg smell” in the hot
water. The smell is a result of four factors which must all be present 
for the odor to develop:
a.  A concentration of sulfate in the supply water.
b.  Little or no dissolved oxygen in the water.
c.  A sulfate reducing bacteria which has accumulated within the water 
heater (this harmless bacteria is nontoxic to humans).
d.  An excess of active hydrogen in the tank. This is caused by the 
corrosion protective action of the anode.
Smelly water may be eliminated or reduced in some water heater models 
by replacing the anode(s) with one of less active material, and then
chlorinating the water heater tank and all water lines. Contact the local 
water heater supplier or service agency for further information concerning 
an Anode Replacement Kit and this chlorination treatment.
If the smelly water persists after the anode replacement and chlorination 
treatment, we can only suggest that chlorination or aeration of the water 
supply be considered to eliminate the water problem.
do not remove the anode leaving the tank unprotected. By 
doing so, all warranty on the water heater tank is voided.
“aIr” In hot water faucets
HYDROGEN  GAS:  Hydrogen  gas  can  be  produced  in  a  hot 
water  system  that  has  not  been  used  for  a  long  period  of  time 
(generally  two  weeks  or  more).  Hydrogen  gas  is  extremely
flammable  and  explosive.  To  prevent  the  possibility  of  injury 
under  these  conditions,  we  recommend  the  hot  water  faucet, 
located farthest away, be opened for several minutes before any 
electrical appliances which are connected to the hot water system 
are used (such as a dishwasher or washing machine). If hydrogen
gas is present, there will probably be an unusual sound similar to 
air escaping through the pipe as the hot water faucet is opened. 
There must be no smoking or open flame near the faucet at the 
time it is open.
hIGh water teMperature shutoff sYsteM
This water heater is equipped with an automatic reset type high 
limit (Energy Cutoff) sensor. The high limit switch interrupts the
main burner gas flow should the water temperature reach 195°F
(91°C).  The  high  limit  will  automatically  reset  when  the  water
temperature  drops  below  140°F  (60°C).  After  cooling  the  tank
temperature, turn off the water heater for at least 10 seconds by 
using the switch on top of the unit. Turn on the water heater. If 
this fails to correct the problem, contact your plumber or service 
representative.
ventInG sYsteM InspectIon
perIodIc MaIntenance
At least once a year a visual inspection should be made of the venting 
system. You should look for:
1.  Obstructions which could cause improper venting.  The combustion 
and ventilation air flow must not be obstructed.
2.  Damage or deterioration which could cause improper venting or 
leakage of combustion products.
Be sure the vent piping is properly connected to prevent escape of 
dangerous flue gasses which could cause deadly asphyxiation.
Obstructions  and  deteriorated  vent  systems  may  present  serious 
health risk or asphyxiation.
Chemical  vapor  corrosion  of  the  flue  and  vent  system  may  occur
if  air  for  combustion  contains  certain  chemical  vapors.  Spray  can 
propellants,  cleaning  solvents,  refrigerator  and  air  conditioner 
refrigerants, swimming pool chemicals, calcium and sodium chloride, 
waxes, bleach and process chemicals are typical compounds which 
are potentially corrosive.
If after inspection of the vent system you found sooting or deterioration, 
something is wrong.  Call the local gas utility to correct the problem 
and clean or replace the flue and venting before resuming operation
of the water heater.