American Water Heater (A)BCG3 85T500-8P Benutzerhandbuch

Seite von 52
9
IS  NOT  SUBJeCT  TO  PhySICAL  DAMAGe  By A  MOVING 
VehICLe.
flammaBle items, PreSSUrIZeD CONTAINerS Or ANy 
OTher  POTeNTIAL  FIre  hAZArDOUS ArTICLeS  MUST 
NeVer  Be  PLACeD  ON  Or ADJACeNT TO The  heATer.  
OPeN  CONTAINerS  Or  FLAMMABLe  MATerIAL  ShOULD 
NOT Be STOreD Or USeD IN The SAMe rOOM WITh The 
heATer.
The heATer MUST NOT Be LOCATeD IN AN AreA Where 
IT WILL Be SUBJeCT TO FreeZING.
LOCATe IT NeAr A FLOOr DrAIN.  The heATer ShOULD 
Be  LOCATeD  IN AN AreA  Where  LeAkAGe  FrOM  The 
heATer Or CONNeCTIONS WILL NOT reSULT IN DAMAGe 
TO The ADJACeNT AreA Or TO LOWer FLOOrS OF The 
STrUCTUre. 
WheN SUCh LOCATIONS CANNOT Be AVOIDeD, A SUITABLe 
DrAIN PAN ShOULD Be INSTALLeD UNDer The heATer.  
Such pans should be fabricated with sides at least 2” deep, with 
length and width at least 2” greater than the diameter of the heater 
and must be piped to an adequate drain.  The pan must not restrict 
combustion air flow.
clearances
This  water  heater  is  approved  for  installation  on  combustible 
flooring (with NSF Leg kit #9003425205) in an alcove when the 
minimum  clearance  from  any  combustible  construction  is  as 
indicated in Figure 6 and Table 4.  
In  all  installations  the  minimum  combustible  clearances  from 
vent piping shall be 6” (15.2 cm). Vent piping passing through a 
combustible wall or ceiling must be a continuous run (no joints) 
and retain the 6” (15.2 cm) clearance unless an approved reducing 
thimble is used.
A service clearance of 24” (61 cm) should be maintained from 
serviceable parts, such as relief valves, flue baffles, thermostats, 
cleanout openings or drain valves.
The units are approved for installation with side, rear and ceiling 
clearances as indicated below:
taBle 4
minimum clearances to comBustiBles in inches (mm)
model
"a"
right
side
"B"
left 
side
"c"
Back
"d"
ceiling
(a)Bcg385t500-8n/ 
(a)Bcg385t500-8p
5"  
(12.7 cm)
5"  
(12.7 cm)
5"  
(12.7 cm)
20" 
(50.8 cm)
taBle 5
minimum clearances to noncomBustiBle construction
model
"a"
right
side
"B"
left 
side
"c"
Back
"d"
ceiling
(a)Bcg385t500-8n/ 
(a)Bcg385t500-8p
0
0
0
12"  
(30.5 cm)
locating the water heater
Property Damage Hazard
All water heaters eventually leak.
Do not install without adequate drainage.
CAUTION
When  installing  the  heater,  consideration  must  be  given  to 
proper  location.    Location  selected  should  be  as  close  to  the 
stack or chimney as practicable, with adequate air supply and as 
centralized with the piping system as possible.
Fire or Explosion Hazard
Read instruction manual before
installing, using or servicing
water heater.
Avoid all ignition sources if you smell gas.
Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
Use only the gas shown on the water heater rating label.
Keep ignition sources away from faucets after extended
periods of non-use.
Maintain required clearances to combustibles.
Do not expose water heater controls to excessive gas
pressure.
There  IS A  rISk  IN  USING  FUeL  BUrNING APPLIANCeS 
SUCh AS GAS WATer heATerS IN rOOMS, GArAGeS Or 
OTher AreAS  Where  GASOLINe,  OTher  FLAMMABLe 
LIQUIDS Or eNGINe DrIVeN eQUIPMeNT Or VehICLeS Are 
STOreD, OPerATeD Or rePAIreD.  FLAMMABLe VAPOrS 
Are heAVy AND TrAVeL ALONG The FLOOr AND MAy Be 
IGNITeD By The heATer’S PILOT Or MAIN BUrNer FLAMeS 
CAUSING  FIre  Or  eXPLOSION.    SOMe  LOCAL  CODeS 
PerMIT OPerATION OF GAS APPLIANCeS IN SUCh AreAS 
IF They Are INSTALLeD 18” Or MOre ABOVe The FLOOr.  
ThIS MAy reDUCe The rISk IF LOCATION IN SUCh AN AreA 
CANNOT Be AVOIDeD.
DO  NOT  INSTALL  ThIS  WATer  heATer  DIreCTLy  ON A 
CArPeTeD FLOOr.  A FIre hAZArD MAy reSULT.  Instead the 
water heater must be placed on a metal or wood panel extending 
beyond the full width and depth by at least 3 inches in any direction.  
If the heater is installed in a carpeted alcove, the entire floor shall 
be covered by the panel.  Also, see the DrAINING requirements 
in MAINTeNANCe Section.
The heATer ShALL Be LOCATeD Or PrOTeCTeD SO IT 
installation considerations