Desa SMS18 Benutzerhandbuch

Seite von 16
www.desatech.com
117536-01B
11
TROUBLESHOOTING
 WARNING: Turn off log set and let cool before servicing. Only a 
qualified service person should service and repair log set.
Note: 
All troubleshooting items are listed in order of operation.
POSSIBLE  CAUSE
1. Poor fuel quality
2. Fireplace venting system not 
drafting properly
3. Excessive flame impingement 
or blockage
4. Improper fuel/air mixture
5. Excessive gas supply/pressure
1. Passage of air/gas across ir-
regular surfaces
1. Incorrect  gas  supply  or 
pressure
2. Blocked  burner  orifice  or 
burner manifold ports
3. Improper burner orifice size
REMEDY
1. Contact  local  natural  gas 
company
2. Adjust  damper  wide  open 
and/or have fireplace and vent-
ing professionally cleaned and 
checked
3. Separate the logs to allow more 
flame passage
4. Remove any foreign items from 
the flame pattern and/or check 
for proper orifice sizing
5. Preheat  flue  in  very  cold 
weather
1. Relieve  any  tight  bends  or 
kinks in gas supply line 
1. Check for proper gas supply 
pressure
2. Free burner orifice and mani-
fold ports of any burrs, paint, 
or other blockage
3. Verify  proper  burner  orifice 
sizing (see Figure 2, page 5)
OBSERVED PROBLEM
Log  set  is  smoking/sooting 
excessively (Note: It is natural 
and unavoidable for vented gas 
log  sets  to  produce  moderate  
levels  of  carbon  (soot)  where 
flames contact the logs.)
Burner is excessively noisy
(Note: The movement and com-
bustion  of  gas  will  create  low, 
unavoidable levels of noise.)
Burner  flame  is  too  low  or  too 
high