OPERATOR’S MANUAL
67072
RELEASED:
3-7-06
REVISED:
1-05-10
(REV. G)
67072 CYCLE CONTROLLER
(PNEUMATIC COUNTDOWN TYPE)
FOR 3/8”, 1/2” & 1” DIAPHRAGM PUMPS WITH 1/4” AIR INLETS
67072 CYCLE CONTROLLER RETRO-FIT KIT.
This kit includes additional parts to do a field retro-fit to standard pumps
models as follows:
3/8” -- PD03P-XXX-XXX (refer to page 3).
1/2” -- 66605X-XXX, PD05P-XXX-XXX, PD05P-XXX-XXX-B and
PD05R-XXX-XXX-B (non-metallic air motor)(refer to page 3).
1” --
6661AX-XXX-C, 6661BX-XXX-C (refer to page 3), 66610X-
XXX-C, 66611X-XXX-C, 66612X-XXX-C and 66613X-XXX-C
(refer to page 4).
3/8” and 1/2” Pumps - Pilot plug and replacement “O” ring(s).
1” Pumps - Screws, plate, gaskets, & template for leg modification.
GENERAL DESCRIPTION
The diaphragm pump Cycle Controller Assembly provides logic control
for preset dispensing. When installed on a diaphragm pump, it can moni-
tor the diaphragm pump pulse or cycle and allow the user to accurately
control the number of cycles the pump will produce. This will effectively
allow a preset and repeatable amount of material to be dispensed
through the pumping system.
Pumps used with this counter assembly must be retrofitted with special
parts. These special parts will allow the pump to output a pilot air signal
which is needed to trigger the counter.
The controller assembly, with 1/4” N.P.T. inlet / outlet, includes a pre-as-
sembled countdown counter, palm operated valve, bracket, tubing and
an air regulator with air pressure gauge.
NOTE: This kit is intended to be attached directly to the pump air inlet.
Mounting it a distance from the pump could result in an air pressure drop
in the pilot signal to the counter and may affect the accuracy.
SCHEMATIC VIEW
REGULATOR
R37121- 100
AIR
INLET
PALM
VALVE
E212HP
PUMP
SIGNAL
COUNTER
59802
- 5
- 3
4
2
P
A
Z
Y
AIR
OUTLET
GAUGE
Figure 1
OPERATION
To determine the number of cycles needed to get the desired output, use
the following formula: Divide the amount of material desired by the dis-
placement per cycle to get the counter setting that is needed (refer to the
pump manual).
NOTE: For best results, operate the pump at 30 - 90 p.s.i. (2.1 - 6.2
bar). Fluctuations in the air pressure can affect the displacement per
cycle. Once the desired displacement is achieved, keep the air pressure
as constant as possible.
BASIC OPERATION
1. Connect air to pump.
2. Set cycle count: Hold the reset button down while entering a new
number of cycles on the counter.
3. Press the palm button to start the cycle.
4. The pump will automatically shut off and reset to the count originally
set.