SECTION TSM 288
ISSUE
A
PAGE 3 OF  36
Source 
of Hazards
Potential 
Hazards
Frequency 
of Hazards
Recommended 
Measures
Unvented 
Cavities
Build up of explosive gas
Very Rare
Ensure that pump is totally 
filled. Consider mounting 
ports vertically. 
Casing / 
Rotors / 
Head
Unintended mechanical 
contact
Rare
Ensure that operating 
pressures are not 
exceeded. Ensure that 
sufficient NPSH to prevent 
cavitation. Service Plan.
Pump 
External 
Surfaces
Excess temperature. 
Electrostatic charging
Rare
User must ensure 
temperature limits. Do not 
overfill gearboxes with 
lubricant. Provide a ground 
contact for pump. 
Service plan.
Cover 
O-Ring
Pump liquid leakage. 
Build up of explosive gas
Very Rare
Check selection of 
elastomers are suitable for 
application. Ensure cover 
retaining nuts are tight. 
Service plan.
Pump 
Casing / Cover
Pump liquid leakage. 
Build up of explosive gas
Very Rare
Stainless Steel. 
Corrosion Resistant.
Shaft Seals
Excessive temperature. 
Unintended mechanical 
contact. Leakage. Build 
up of explosive gas
Rare
Selection of seal system 
must be suitable for 
application. Manual. 
Service plan. Seals must 
never run dry.
Auxiliary 
System for 
Shaft 
Sealing
Pump liquid leakage.
Build up of explosive gas
Rare
Selection of auxiliary seal 
system must be suitable 
for application. Seals must 
never run dry.
Rotation 
Direction 
Test
Excess Temperature
Very Rare
If flushed seals are 
installed, ensure that 
flush is applied to seal 
assemblies. Only allow 
pump to run for minimum 
period - just a few seconds.
Closed 
Valve 
Condition
Excess Temperature. 
Excess Pressure. 
Mechanical Contact
Rare
Can cause excessive 
pressure, heat and 
mechanical contact. 
Manual.
Shaft
Random induced current
Very Rare
Provide a ground  
contact for pump.
Mechanical 
Shaft 
Coupling
(Torque 
Protection)
Temperature from 
friction. Sparks from 
break up of shear pins. 
Electrostatic charging
Rare
Coupling selection must 
suit application. 
Provide ground  
contact for pump.
Mechanical 
Shaft 
Coupling
(Standard)
Break up of spider. 
Unintended  
mechanical contact. 
Electrostatic charging
Rare
Coupling selection must 
suit application. Service 
plan. Provide ground 
contact for pump.
NOTE
for  a  feature  to  be  suitable  for  an  application,  the 
feature must be fit for its designated purpose and also 
suitable for the environment where it is to be installed.
1.1  RIsK assEssMENT RElaTING 
TO THE UsE Of VIKING PUMP 
sl sERIEs ROTaRY lObE 
PUMPs aNd PUMP UNITs IN 
POTENTIallY EXPlOsIVE 
aTMOsPHEREs
2.0  INTROdUCTION
2.1  GENERal
SL  Series  rotary  lobe  pumps  are  manufactured  by  Johnson 
Pump (UK) Ltd. , a subsidiary of Viking Pump Co., (a unit of the 
IDEX Corporation).
This  manual  includes  all  the  necessary  information  for  SL 
Series pumps and should be read prior to beginning installation, 
operation, or maintenance.
Should  you  require  any  additional  information  regarding  the 
SL Series pumps contact Viking Pump or their local authorized 
distributor, refer to section 2.2.
When asking for assistance please provide the pump model 
and serial number. This information can be obtained from the 
pump nameplate which is located on the side of the bearing 
housing, refer to section 2.7.
Should  the  nameplate  be  unreadable  or  missing  the  serial 
number is also stamped on either side of the casing refer to 
section 2.7.
If the system or product characteristics are to be changed from 
the  original  application  for  which  the  pump  was  selected,  or 
their authorized distributor should be consulted to ensure the 
pump is suitable for the new application.
2.2  VIKING PUMP  dIsTRIbUTORs
Viking Pump distributes its products internationally via a network 
of  authorized  distributors.  Throughout  this  manual  where 
reference is made to Viking Pump, service and assistance will 
also be provided by any Viking Pump authorized distributor for 
SL Series pumps.
2.3  RECEIPTs aNd sTORaGE
Upon receipt of the pump, immediately examine it for any signs 
of  visible  damage.    If  any  damage  is  noted,  contact  Viking 
Pump or your Viking Pump distributor and clearly mark upon 
the carriers’ paperwork that the goods have been received in a 
damaged condition, with a brief description of damage. 
If  the  pump  is  not  required  for  immediate  installation  then  it 
should be stored in a clean, dry environment. It is recommended 
that storage temperature should be between –10°C and 40°C 
(14°F and 105°F).
Additionally, if the pump is not intended for installation or use 
within 18 months or more then refer to Viking Pump or the Viking 
Pump authorized distributor for storage recommendations.
2.4  ClEaNING
The SL Series pump range is suitable for manual cleaning and 
in-line cleaning refer to section 3.4.1.
The  mechanical  seals  are  mounted  directly  behind  the  rotor 
and  are  designed  and  to  minimize  product  entrapment  and 
maximize the effects of cleaning.
This strategic positioning of the mechanical seals, combined 
with their ease of access provides an arrangement that can be 
more effectively cleaned by both manual and in-line cleaning 
procedures.
Whenever the pump head is dismantled, and at regular intervals 
as  determined  by  local  operating  conditions  and  verified 
cleaning  procedures,  including  installations  where  the  pump 
is only operated using n-line cleaning procedures, the areas 
behind the rotor case adjacent to the mechanical seals and the