Use only a 3-wire extension cord that has a 3-blade grounding
plug and a 3-slot receptacle that will accept the plug on the
product.  Make sure your extension cord is in good condition.
When using an extension cord, be sure to use one heavy
enough to carry the current your product will draw.  An
undersized cord will cause a drop in line voltage resulting in
loss of power and overheating.  A 14 or 12 gauge cord is
recommended.
Grounding instructions
This product must be grounded. In the event of an electrical
short circuit, grounding reduces the  risk of electric shock by
providing an escape wire for the electric current. This product
is equipped with a cord having a grounding wire with an
appropriate grounding plug. The plug must be plugged into an
outlet that is properly installed and grounded in accordance
with all local codes and ordinances.
This product is for use on a nominal 120 volt circuit and has a
grounding plug that looks like the plug illustrated in sketch A.
If a properly grounded outlet is not available, a temporary
adapter which looks like the adapter illustrated in sketch B and
C may be used.  The  temporary  adapter should be used only
until a properly grounded outlet can be installed by a qualified
electrician. The green colored rigid  ear lug or the grounding
wire extending from the adapter must be connected to a
permanent ground such as a properly grounded outlet box
cover. Whenever the adapter is used, it must be held  in place
by a metal screw.
Improper installation of the grounding plug can result in a risk
of electric shock.
If repair or replacement of the cord or plug is necessary, do not
connect the green grounding wire to either flat blade terminal.
The wire with insulation having a green outer surface with or
without yellow stripes is the grounding wire and must be
connected to the grounding pin.
Check with a qualified electrician or serviceman if the
grounding instructions are not completely understood, or if you
are in doubt as to whether the product  is properly grounded.
Do not modify the plug provided.  If the plug will not fit the
outlet, have the proper outlet installed by a qualified
electrician.
Extension Cord Selection
If an extension cord is used, make sure that it is of the 3-
conductor type with NEMA connectors so a continuous
grounding circuit is provided from the tool to the power circuit
receptacle.  Also, be sure that the conductor size is large
enough to prevent excessive voltage drop which will cause
loss of power and possible motor damage to the unit.  A table
of recommended extension cord sizes is shown below.
For nameplate ampere ratings which are between those given,
use the extension cord recommended for the next higher
ampere rating.
WARNING
(A)
(B)
(C)
CAUTION
4
© SprayTECH Corporation.  All rights reserved.
If an extension cord is to be used outdoors, it must be marked with
the suffix W-A following the cord type designation.  For example,
SJTW-A to indicate that it is acceptable for outdoor use.
Initial Setup
The Piston Pump unit is fully assembled upon delivery.  Follow
these simple steps for setup: 
1. Pull up on the handle until the button locks snap into place.
Purging the sprayer
This unit is shipped with test fluid in the fluid section to prevent
corrosion during shipment and storage.
If you are going to spray with latex paint, the test fluid must be
purged and then thoroughly cleaned out of the system.
If you are going to spray with solvent-based paint, all you need
to do is purge the fluid.  Thorough cleaning is not necessary.
Keep the spray gun locked and in the OFF position during
these steps. 
Purging the system for latex paint
1. Place a container of soapy water under the paint suction tube.
Have a  waste container ready to catch the purged fluid.
2. Detach the return tube from the fluid section and place it
in the waste container.
Return Tube
CAUTION
Extension Cord Length
Nameplate Ampere Rating
25 ft.
0 to 5
18
18
18
18
18
18
18
18
18
18
18
16
18
18
18
18
16
16
18
18
18
16
16
16
18
18
18
16
16
14
18
18
18
16
14
14
16
16
16
16
14
14
16
16
16
16
14
14
16
16
16
14
14
14
14
14
14
14
14
12
14
14
14
14
14
12
14
14
14
14
12
12
14
14
14
14
12
12
14
14
14
14
12
12
12
12
12
12
12
12
12
12
12
12
12
12
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
50 ft. 75 ft. 100 ft. 125 ft. 150 ft.
English