Viking SLBL Benutzerhandbuch

Seite von 36
SECTION TSM 288
ISSUE
A
PAGE 12 OF  36
When  removing  and  refitting  lipseals  or  O-rings  care 
should  be  taken  to  avoid  cutting  or  tearing  the  sealing 
faces as they pass over keyways, splines, threads or other 
potentially sharp or abrasive edges. All lipseals and O-rings 
should  be  carefully  examined  and  if  damaged  in  any  way, 
replaced on assembly.
All O-rings and sealing lips of lipseals should be lightly lubricated 
with a suitable lubricant (silicon grease, etc.) before installing.
When installing lipseals do not allow the rear face to come into 
contact with bearings see section 6.3 for details
Prior  to  beginning  assembly,  ensure  all  parts  are  clean  and 
free  from  burrs  or  damage.  Where  a  vice  is  to  be  used,  it 
should have protective jaws to avoid damage to components. 
Do  not  hammer  or  apply  undue  force  to  install  or  position 
components.
All fasteners are required to be tightened to the required torque 
setting during assembly, refer to section 6.2.
The preferred method of installing bearing cones 
is to heat them to approximately 120°C (250°F) 
prior to installation. During this operation protective 
gloves  should  be  used.    Once  bearing  cones 
are  installed  in  correct  position  they  should  be 
allowed to cool before proceeding with assembly.  
As an alternative, bearing cones may be pressed 
into  position  providing  the  proper  equipment  is 
employed  and  the  necessary  procedures  are 
used to prevent component damage.
Under no circumstances should bearing cones or cups be 
hammered into position.
4.0  sl sERIEs PUMP dIsMaNTl- 
ING aNd assEMblY
Before  undertaking  any  work  on  the  pump  the 
recommended  shutdown  procedure  should  be 
followed,  refer  to  section  3.6,  and  site  safety 
practices must be observed.
While  dismantling  or  assembling  the  pump  it 
is  essential  to  ensure  that  the  pump  and/or 
components  are  secured  to  provide  adequate 
stability.
Large  pump  components  or  sub  assemblies 
should  be  lifted  using  suitable  devices.  Use 
threaded holes for the attachment of lifting eyes 
where appropriate.
During dismantling or before assembly all components should 
be inspected for fit, wear, and damage. If worn or damaged the 
components should be replaced before re-assembly.
The position of all parts should be identified as they are removed 
to ensure they are reinstalled in the same position.
Lipseals  and  O-rings  are  incorporated  within  the  bearing 
housing  assemblies  and  the  gearbox  cover  to  contain  the 
lubricant for the bearings and timing gears. Regular inspection 
and  correct  maintenance  of  these  items  will  ensure  that  the 
lubrication is sustained and the pump maximum working life is 
achieved. To ensure this, it is extremely important that care is 
taken when removing and installing new O-rings and lipseals. 
When removing and replacing lipseals ensure that the location 
bore for the outside diameter and the seat for the back of the 
lipseal is not damaged as this may create a leak path for the 
lubricant.
3.9.2 JaCKETEd CasING
slas
slal
slbs
slbl
slCs
slCl
slds
sldl
slEs
slEl
slfs
slfl
a
28
42.4
54.5
65.5
86
67
b
54.5
62
70
93
95
102
C
45
60
66.5
89
117
132
d
1/8” BSP
E
37 - 39
41 - 43
41 - 43
46 - 48
44 - 46
52 - 54
51 - 53
61 - 63
53 - 55
65 - 67
65 - 67
80 - 82
!
!
!
!