Viking SLBL Benutzerhandbuch

Seite von 36
fIGURE 8
10
.0
M
et
er
s
(3
2.
8
Fe
et
)W
at
er
C
ol
um
n
Suction Lift
Or Vacuum
Atmospheric
Pressure
Suction
Head
NPSH
Available
Suction Line
Friction Loss
Vapour
Pressure
NPSH
Available
Suction Line
Friction Loss
Vapour
Pressure
For Suction Lift
Or Vacuum
Conditions.
For Conditions
With Positive
Suction Head.
Atmospheric
Vacuum
fIGURE 7
Pump 
series
Theoretical  
displacement
Nominal  
Connection  
size
Max diff. 
Pressure
Max 
speed
Max 
Temp
liter
/rev
Imp. Gal 
/100 rev
Us gal 
/100 rev mm
in.
bar psi
rev 
/min
°C °f
SLAS 0.039
0.86
1.03
19
3/4”
15 218 1400 150 300
SLAL 0.059
1.30
1.56
25
1”
10 145 1400 150 300
SLBS 0.081
1.78
2.14
25
1”
15 218 1200 150 300
SLBL 0.122
2.68
3.22
38 1 1/2” 10 145 1200 150 300
SLCS 0.169
3.72
4.46
38 1 1/2” 15 218 1200 150 300
SLCL 0.254
5.59
6.71
50
2”
10 145 1200 150 300
SLDS 0.352
7.74
9.30
38 1 1/2” 15 218 1000 150 300
SLDL 0.528
11.61
13.95
50
2”
10 145 1000 150 300
SLES 0.732
16.10
19.34
50
2”
15 218
800 150 300
SLEL 1.099
24.18
29.03
76
3”
10 145
800 150 300
SLFS 1.524
33.52
40.26
76
3”
15 218
600 150 300
SLFL 2.285
50.26
60.36
101
4”
10 145
600 150 300
SLGS 3.17
69.73
83.74
101
4”
15 218
600 150 300
SLGL 4.754 104.58
125.59 152
6”
10 145
600 150 300
SLHS
6.4
140.78
169.07 152
6”
15 218
600 150 300
SECTION TSM 288
ISSUE
A
PAGE 6 OF  36
Pressure  gauges  should  be  installed  adjacent 
to the pump suction and discharge connections 
such  that  system  pressures  can  be  monitored. 
These  gauges  will  provide  a  clear  indication  of 
changes  in  operating  conditions  and  where  a 
relief valve is incorporated in the system, will be 
necessary for setting and checking the functioning 
of the valve.
It is imperative that the suction condition at the 
pump inlet meets the Net Positive Suction Head 
required (NPSHr) by the pump. Failure to observe 
this  could  cause  cavitation,  resulting  in  noisy 
operation, reduction in flow rate and mechanical 
damage to the pump and associated equipment. 
The Net Positive Suction Head available (NPSHa) 
from  the  system  must  always  exceed  the  Net 
Positive Suction Head required (NPSHr) by the 
pump.
Observing the following general guidelines should ensure the 
best possible suction condition is created.
•  Suction  piping  is  at  least  the  same  diameter  as  the  pump 
connections.
•  The  length  of  suction  piping  is  kept  to  the  absolute 
minimum.
•  The  minimum  number  of  bends,  tees  and  pipework 
restrictions are used.
•  Calculations to determine system NPSHa are carried out for 
the worst condition see below.
Should  advice  on  pump  or  system  NPSH  characteristics  be 
required contact the factory or their authorized distributor.
3.4  sYsTEM dEsIGN aNd  
INsTallaTION
When incorporating any pump into a system it is considered 
good practice to minimize piping runs and the number of pipe 
fittings (tees, unions, bends etc.) and restrictions.  Particular 
care  should  be  taken  in  designing  the  suction  line,  which 
should be as short and straight as possible with a minimum of 
pipe fittings to minimize restricting product flow to the pump. 
The following should be considered at the design stage of any 
system.
Be sure ample room is provided around the pump 
to allow for:
•  Access  to  the  pump  and  drive  for  routine 
inspection  and  maintenance,  i.e.  to  remove 
pump head and rotors.
•  Ventilation  of  the  drive  to  prevent  over 
heating.
The exterior of the pump unit may exceed 68°C 
(154°F); Appropriate measures must be taken to 
warn or protect operators.
The  pump  must  not  be  used  to  support  piping. 
All  piping  to  and  from  the  pump  unit  must  be 
independently  supported.    Failure  to  observe 
this  may  distort  the  pump  head  components 
or  assembly  and  cause  serious  consequential 
damage to the pump.
Valves should be provided adjacent to the pump 
suction  and  discharge  connections  to  allow  the 
pump to be isolated from the system for routine 
inspection and maintenance.
Rotary lobe pumps are of the positive displacement 
type and therefore an overload protection device 
must be provided. This can take the form of:
•  An in-line pressure relief system, i.e. external 
to the pump.
•  Incorporation of a torque-limiting device in the 
drive system.
It is recommended that all piping and associated 
equipment from the tank to the discharge point 
is  thoroughly  cleaned  before  installation  of  the 
pump to avoid  the possibility  of debris  entering 
the pump and causing damage.
WaRNING
WaRNING
WaRNING
WaRNING
WaRNING
!
!
!