For Integral Relief Valve with Manual Lift - see Figure 11.
•  To  operate  the  manual  lift,  turn  the  hand  wheel  (111)  
clockwise,  which  will  lift  the  valve  head  (102/128).    To 
resume  normal  operation  turn  the  hand  wheel  (111)  
counter-clockwise.
For Integral Relief Valve with airlift - see Figure 13.
•  To actuate the air lift connect an air supply not exceeding 7 
Bar for SLA -E and 10 Bar for SLF to the cylinder (123) which 
will lift the valve head (112). To resume normal relief valve 
operation, exhaust the Cylinder (123).  
3.8.2 sETTING aNd OPERaTING aIR 
lOadEd ValVE
See Figure 14.
•  Connect  an  air  supply,  via  a  regulating  valve  to  the  relief 
valve connection A in the cylinder (114). Do not turn on the 
air supply.
•  Start the pump, refer to section 3.5.
•  Using the regulating valve gradually increase the air pressure 
until  required  pressure  relief  setting  is  reached.  The  air 
pressure must not exceed 7 Bar SLA - E and 10 Bar SLF.
•  The relief valve is now set.
•  slf  Only  -  If  the  valve  assembly  is 
disassembled,  e.g.  for  maintenance  or 
repair,  it  is  necessary  to  apply  a  thread 
locking compound (loctite 270 or similar) 
to the piston retaining screw (120).
NOTE: Care  should be taken  not to exceed  the lower of 
either the pumps maximum pressure rating or the system 
design pressure.
•  To use the air lift system the regulated air supply must be 
routed  through  a  change  over  valve  in  order  to  transfer 
air  from  the  relief  valve  load  air  chamber,  connection A, 
to the lift air chamber, connection B while depressurizing 
the load chamber and vice versa. The change over valve 
will actuate the air lift which will lift when the air supply is 
diverted to connection B, and will close, restoring normal 
relief valve operation, when the air supply is diverted back 
to connection A.
Spring Loaded Integral Pressure Relief Valve 
SLA – E  Typical.
Spring Loaded Integral Pressure Relief Valve with Manual Lift 
SLA - E Typical.
WaRNING
daNGER !
Under  no  circumstances  should  any 
attempt be made to dismantle a pressure 
relief valve which has not had the spring 
pressure relieved, is still connected to 
a pressurized air supply, or is mounted 
on  a  pump  that  is  operating.    serious 
personal  injury  or  pump  damage  may 
occur.
!
!