DO NOT OPERATE PUMP IF:
–  The front cover is not installed correctly 
–  Any guards are missing or incorrectly installed 
–  The suction or discharge piping is not connected  
DO NOT place fingers, etc  into the pumping chamber 
or its connection ports or into any part of the drive train 
if there is ANY possibility of the pump shafts being 
rotated  Severe injury will occur 
DO NOT exceed the pumps rated pressure, speed, and 
temperature, or change the system/duty parameters 
from those for which the pump was originally supplied, 
without confirming its suitability for the new duty 
INSTALLATION AND OPERATION OF THE PUMP 
MUST ALWAYS COMPLY WITH HEALTH AND 
SAFETY REGULATIONS.
Rare earth magnets used in couplings have 
extremely strong magnetic fields capable of 
changing performance or damaging items such as: 
Pacemakers, Metal Implants, Watches, Computers 
& Disks, and Credit Cards
Completely assembled magnetic couplings will 
not affect items listed above - only disassembled 
components 
There are no known harmful effects of these 
magnetic fields on the human body 
A device must be incorporated into the pump, system, 
or drive to prevent the pump exceeding its stated duty 
pressure  It must be suitable for both directions of 
pump rotation where applicable  Do not allow pump 
to operate with a closed/blocked discharge unless a 
pressure relief device is incorporated  If an integral 
relief valve is incorporated into the pump, do not allow 
re-circulation through the relief valve for extended 
periods 
The mounting of the pump or pump unit should be  
solid and stable  Pump orientation must be considered 
in relation to drainage requirements  Once mounted, 
shaft drive elements must be checked for correct 
alignment  Rotate pump shaft by at least one full 
revolution to ensure smoothness of operation  
Incorrect alignment will produce excessive loadings 
and will create high temperatures and increased noise 
emissions  Do not use any drive arrangements which 
cause sideloading of the drive shaft  
The installation must allow safe routine maintenance 
and inspection (to check for leakage, monitor 
pressures, etc) and provide adequate ventilation 
necessary to prevent overheating 
Before operating the pump, be sure that it and all 
parts of the system to which it is connected are clean 
and free from debris and that all valves in the suction 
and discharge pipelines are fully opened  Ensure that 
all piping connecting to the pump is fully supported 
and correctly aligned with its relevant connections  
Misalignment and/or excess loads will cause severe 
pump damage 
Be sure that pump rotation is correct for the desired 
direction of flow 
DO NOT INSTALL THE PUMP INTO A SYSTEM 
WHERE IT WILL RUN DRY (I.E. WITHOUT A 
 
SUPPLY OF PUMPED MEDIA).
Pressure gauges/sensors are recommended, next 
to the pump suction and discharge connections to 
monitor pressures 
Caution must be taken when lifting the pump  Suitable 
lifting devices should be used as appropriate  Lifting 
eyes installed on the pump must only be used to lift  
the pump, not pump with drive and/or baseplate  If 
pump is baseplate mounted, the base plate must be 
used for all lifting purposes  If slings are used for lifting, 
they must be safely and securely attached  For weights 
of bare shaft pumps refer to catalog 
DO NOT attempt any maintenance or disassembly of 
the pump or pump unit without first ensuring that : 
–  The pump is fully isolated from the power source 
(electric, hydraulic, pneumatic) 
– The pumping chamber, relief valve and any 
shaft seal support system are depressurized and 
purged 
–  Any temperature control devices (jackets, heat-
tracing, etc) are fully isolated, that they are 
depressurized and purged, and components are 
allowed to reach a safe handling temperature 
DO NOT attempt to dismantle a pressure relief valve 
which has not had the spring pressure relieved or is 
mounted on a pump that is operating  Serious personal 
injury or death and/or pump damage may occur 
DO NOT loosen or undo the front cover, any 
connections to the pump, shaft seal housings, 
temperature control devices, or other components, 
until sure that such action will not allow the unsafe 
escape of any pressurized media 
Pumps and/or drives can produce sound power levels 
exceeding 85 dB(A) under certain operating conditions  
When necessary, personal protection against noise 
must be taken 
Avoid any contact with hot parts of pumps and/or  
drives which may cause injury  Certain operating 
conditions, temperature control devices (jackets, heat-
tracing, etc ), bad installation, or poor maintenance 
can all promote high temperatures on pumps and/or 
drives 
WARNING
SAFETY INFORMATION
Danger - Failure to follow the listed 
precautionary measures identified by 
this symbol may result in serious injury 
or death 
Warning - Safety instructions which 
shall be considered for reasons of safe 
operation of the pump or pump unit and/
or protection of the pump or pump unit 
itself are marked by this symbol 
INCORRECT INSTALLATION, OPERATION OR MAINTENANCE OF EQUIPMENT MAY CAUSE SEVERE 
PERSONAL INJURY OR DEATH AND/OR EQUIPMENT DAMAGE AND MAY INVALIDATE THE WARRANTY.
This information must be read fully before beginning installation, operation or maintenance and must be 
kept with the pump. All installation and maintenance must be undertaken by suitably trained or qualified 
persons only.
WARNING