M968852 Rev.1.3
4
3
INSTALL HANDLES
GROOVE
GROOVE
FINISHED WALL
1
1
4
8
9
5
6
7
4
2
DRAIN INSTALLATION
Assembly GASKET (2) WASHER (3) and LOCKNUT (4) onto DRAIN BODY (1).
Tighten LOCKNUT (4) firmly. 
Assembly TAILPIECE (5) to DRAIN BODY (1).
Apply a bead of PUTTY to underside of FLANGE on DRAIN BODY (1).
Feed DRAIN BODY (1) down through lavatory.
LAVATORY
PUTTY
2
3
4
5
1
2
INSTALL WALL SPOUT
Remove PLASTER GUARDS (1) from valve bodies.
Inspect that SPOUT NIPPLE O-RING (2) is seated in groove of SPOUT NIPPLE (3).
Thread SPOUT MOUNT (4) onto SPOUT NIPPLE (3). Align groove on SPOUT MOUNT (4)
with face of finished wall. See Figure A.
Install SEAL (5) into SPOUT ESCUTCHEON (6). Place SPOUT
ESCUTCHEON (6) with SEAL (5) onto SPOUT MOUNT (4).
Push SPOUT (7) onto SPOUT MOUNT (4). Align SPOUT (7)
and tighten SPOUT SET SCREW (8) with 3mm HEX WRENCH
(9) supplied.
 
Figure A
1
MAX
W
A
L
M
IN
1-5
/8"DE
MAXW
AL
L
M
IN
1-5
/8"D
EEP
3
1
5
2
3
4
Thread HANDLE BASE (4) onto HANDLE ESCUTCHEON (3)
until seated tightly against HANDLE ESCUTCHEON (3).
 
Place O-RING (2) into HANDLE ESCUTCHEON (3).
Thread HANDLE ESCUTCHEON (4) onto VALVE (5) until
snug against finished wall.
Turn VALVE STEMS (1) to off position.