PROGRAMMABLE WALL SWITCH 
MODEL TI052A-3W / 3-WAY
FOR ALL LIGHTING
THE MAXIMUM LOAD MUST NOT EXCEED 500W/230V
SINGLE POLE INSTALLATION
When installing, do not connect the red wall switch wire. Make sure the
red wire is correctly capped with a wire nut.
WIRING DIAGRAM
INSTALLATION
This  wall  switch  can  be  used  for  either  single  pole  or  multiswitch
installation.
A  multiswitch  installation  with  an  electronic  wall  switch  differs  from
conventional  installation.  Read  wiring  instructions  carefully.  Use
guidelines applicable to your installation.
Apply the following steps for all installations.
Note: The  black  wall  switch  wires  have  no  polarity.  You  can  use  any
of them.
1. Interrupt power at circuit breaker to avoid electric shock.
2. Take  out  and  disconnect  existing  switch  for  replacement  (for
multiswitch  installation,  identify  the  wire  connected  on  the
" common " screw).
3. Reconnect  each  disconnected  wire  to  the  timer  according  to  the
appropriate wiring diagram.
4. Put back switches correctly into their electric box.
5. Return power at circuit breaker.
EXISTING 3-WAY INSTALLATION
To  replace  a  3-way  switch  with  this  wall  switch,  use  the  following
diagram :
TO VERIFY OPERATION
Refer to " POWER-ON " section to start the wall switch.  Try turning on
lights  with  remote  switch  and  wall  switch.  Installation  is  completed  if
operations  run well.  If it does not function properly, interrupt power  at
circuit breaker and rewire the jumper on the remote switch between the
" common " screw and the other screw.
A NEW 3-WAY INSTALLATION
For a new installation, a single pole switch can be used at the remote
location. Use the following wiring diagram :
Note: The jumper wire provided is not used for this installation.
POWER-ON
1. Open the wall switch door using a small screwdriver.
2. Ensure that the fuse is properly installed
3. Press on the " reset " button using a paper clip.
4. On the display, " 0:00 " and " MO " should flash.
If there is nothing on the screen, check the following points :
a) Maybe the fuse is not present in the switch.
b) If  the  wall  switch  controls  a  lamp  equipped  with  an  on/off  switch,
make sure the lamp switch is in " ON " position.
THE TI052A-3W WALL SWITCH CAN OPERATE ON :
ballast equipped installations such as : fluorescent lamps, sodium
lamps, etc.
incandescent and halogen lighting
contactor equipped installations, ceiling fan, block heater, etc.
The " common " wire identified on the removal  3-way  switch  must  be
connected on either black wall switch wires. Connect the two other wall
switch wires to the two remaining wires.
On the remote switch, connect the jumper wire between the " common
" screw of the switch and the screw where the second black wall switch
wire is connected. Once wiring is completed, put switches back in their
electric box and return power at circuit breaker.
720-052002   1/2