StorageTek 312564001 Benutzerhandbuch

Seite von 189
 
124 
DB2 Manager User Guide 
 StorageTek 
Proprietary 
reason for the error can be identified, contact your local STK support 
representative. 
 
OTD10021 
Insufficient storage for workareas 
 Explanation:  An attempt by the utility to allocated virtual storage has failed 
Execution of the utility will be terminated with condition code 12. 
 
Action:  Increase the region size specified for execution of the utility and re-
submit the job. 
 
OTD10022 
Table migration utility terminating in response to operator request 
 Explanation:  This message is displayed on the system console to acknowledge 
receipt of an operator STOP command by the utility.   Execution of the 
utility will terminate with condition code 4.  
 
Action:  None.  This is an informational message. 
 
OTD10023 
Execution terminated in response to operator request 
 Explanation:  This message is displayed at jobstep completion when execution of 
the utility has been terminated via an operator STOP command.   
 
Action:  None.  This is an informational message. 
 
OTD10024 
Non-index fields specified in SELECT statement in SQLIN file 
 Explanation:  One or more of the columns specified for retrieval in the SELECT 
statement in the SQLIN file do not appear in the unique table index.   
Execution of the utility is terminated with condition code 12. 
 
Action:  The columns specified in the SELECT statement must uniquely index 
each row in the table (see page 85 for a description of SQLIN file 
specification).   Correct the SQLIN entry and re-submit the job.